TY - JOUR
T1 - Laboratory diffracted x-ray blinking to monitor picometer motions of protein molecules and application to crystalline materials
AU - Arai, Tatsuya
AU - Inamasu, Rena
AU - Yamaguchi, Hiroki
AU - Sasaki, Daisuke
AU - Sato-Tomita, Ayana
AU - Sekiguchi, Hiroshi
AU - Mio, Kazuhiro
AU - Tsuda, Sakae
AU - Kuramochi, Masahiro
AU - Sasaki, Yuji C.
N1 - Funding Information:
The content related to the measurements of BSA and AFP was supported by Grants-in-Aids (Nos. JP20H04660, JP20H04696, and 21K14466) for scientific research from the Japan Society for the Promotion of Science. The content related to the measurement of crystalline polymer is the result of implementation as one of the comprehensive joint research signed to university-corporate relations agreement between University of Tokyo and Daikin Industries, Ltd.
Publisher Copyright:
© 2021 Author(s).
PY - 2021/7/1
Y1 - 2021/7/1
N2 - In recent years, real-time observations of molecules have been required to understand their behavior and function. To date, we have reported two different time-resolved observation methods: diffracted x-ray tracking and diffracted x-ray blinking (DXB). The former monitors the motion of diffracted spots derived from nanocrystals labeled onto target molecules, and the latter measures the fluctuation of the diffraction intensity that is highly correlated with the target molecular motion. However, these reports use a synchrotron x-ray source because of its high average flux, resulting in a high time resolution. Here, we used a laboratory x-ray source and DXB to measure the internal molecular dynamics of three different systems. The samples studied were bovine serum albumin (BSA) pinned onto a substrate, antifreeze protein (AFP) crystallized as a single crystal, and poly{2-(perfluorooctyl)ethyl acrylate} (PC8FA) polymer between polyimide sheets. It was found that not only BSA but also AFP and PC8FA molecules move in the systems. In addition, the molecular motion of AFP molecules was observed to increase with decreasing temperature. The rotational diffusion coefficients (DR) of BSA, AFP, and PC8FA were estimated to be 0.73 pm2/s, 0.65 pm2/s, and 3.29 pm2/s, respectively. Surprisingly, the DR of the PC8FA polymer was found to be the highest among the three samples. This is the first report that measures the molecular motion of a single protein crystal and polymer by using DXB with a laboratory x-ray source. This technique can be applied to any kind of crystal and crystalline polymer and provides atomic-order molecular information.
AB - In recent years, real-time observations of molecules have been required to understand their behavior and function. To date, we have reported two different time-resolved observation methods: diffracted x-ray tracking and diffracted x-ray blinking (DXB). The former monitors the motion of diffracted spots derived from nanocrystals labeled onto target molecules, and the latter measures the fluctuation of the diffraction intensity that is highly correlated with the target molecular motion. However, these reports use a synchrotron x-ray source because of its high average flux, resulting in a high time resolution. Here, we used a laboratory x-ray source and DXB to measure the internal molecular dynamics of three different systems. The samples studied were bovine serum albumin (BSA) pinned onto a substrate, antifreeze protein (AFP) crystallized as a single crystal, and poly{2-(perfluorooctyl)ethyl acrylate} (PC8FA) polymer between polyimide sheets. It was found that not only BSA but also AFP and PC8FA molecules move in the systems. In addition, the molecular motion of AFP molecules was observed to increase with decreasing temperature. The rotational diffusion coefficients (DR) of BSA, AFP, and PC8FA were estimated to be 0.73 pm2/s, 0.65 pm2/s, and 3.29 pm2/s, respectively. Surprisingly, the DR of the PC8FA polymer was found to be the highest among the three samples. This is the first report that measures the molecular motion of a single protein crystal and polymer by using DXB with a laboratory x-ray source. This technique can be applied to any kind of crystal and crystalline polymer and provides atomic-order molecular information.
UR - http://www.scopus.com/inward/record.url?scp=85109355156&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85109355156&partnerID=8YFLogxK
U2 - 10.1063/4.0000112
DO - 10.1063/4.0000112
M3 - Article
AN - SCOPUS:85109355156
SN - 2329-7778
VL - 8
JO - Structural Dynamics
JF - Structural Dynamics
IS - 4
M1 - 044302
ER -