TY - JOUR
T1 - Line-focus array transducers for effective actuation of tissue
AU - Sawada, Tomotaka
AU - Hasegawa, Hideyuki
AU - Kanai, Hiroshi
PY - 2010/7
Y1 - 2010/7
N2 - Acoustic radiation forces induced by ultrasound can be used to apply external forces to an object, and the viscoelastic property of the object can be evaluated by measuring the resultant regional displacement of the object using a different ultrasonic probe for measurement. However, according to safety guidelines for the use of ultrasound, the recommended intensity is below 1W/cm2 for continuous waves. Therefore, to generate a measurable displacement or strain by acoustic actuation, a method of effectively applying acoustic radiation forces needs to be devised. A potential way to improve the efficiency of acoustic actuation is to use line-focus transducers. However, there are undesired fluctuations in the emitted sound field due to the finite aperture size with uniform apodization when a single-element line-focus transducer (SELFT) is used to emit plane waves, which are focused only in the elevational direction. To suppress such undesired fluctuations, in the present study, a pair of linefocus array transducers (LFATs) was constructed to realize spatially smoother radiation forces by applying an appropriate apodization. As a result, the three dominant undesired peaks in the sound field emitted from a SELFT were suppressed using the LFATs with the examined appropriate apodization, and the displacement distribution induced in a phantom, which was measured by the phased tracking method using the different ultrasonic probe, became spatially smooth.
AB - Acoustic radiation forces induced by ultrasound can be used to apply external forces to an object, and the viscoelastic property of the object can be evaluated by measuring the resultant regional displacement of the object using a different ultrasonic probe for measurement. However, according to safety guidelines for the use of ultrasound, the recommended intensity is below 1W/cm2 for continuous waves. Therefore, to generate a measurable displacement or strain by acoustic actuation, a method of effectively applying acoustic radiation forces needs to be devised. A potential way to improve the efficiency of acoustic actuation is to use line-focus transducers. However, there are undesired fluctuations in the emitted sound field due to the finite aperture size with uniform apodization when a single-element line-focus transducer (SELFT) is used to emit plane waves, which are focused only in the elevational direction. To suppress such undesired fluctuations, in the present study, a pair of linefocus array transducers (LFATs) was constructed to realize spatially smoother radiation forces by applying an appropriate apodization. As a result, the three dominant undesired peaks in the sound field emitted from a SELFT were suppressed using the LFATs with the examined appropriate apodization, and the displacement distribution induced in a phantom, which was measured by the phased tracking method using the different ultrasonic probe, became spatially smooth.
UR - http://www.scopus.com/inward/record.url?scp=77956569736&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77956569736&partnerID=8YFLogxK
U2 - 10.1143/JJAP.49.07HF10
DO - 10.1143/JJAP.49.07HF10
M3 - Article
AN - SCOPUS:77956569736
SN - 0021-4922
VL - 49
JO - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes
JF - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes
IS - 7 PART 2
M1 - 07HF10
ER -