TY - JOUR
T1 - Luminescence and scintillation response of YGd2Al2Ga3O12:Ce and LuGd2Al2Ga3O12:Ce scintillators
AU - Chewpraditkul, Warut
AU - Pattanaboonmee, Nakarin
AU - Chewpraditkul, Weerapong
AU - Kamada, Kei
AU - Yoshikawa, Akira
AU - Nikl, Martin
N1 - Publisher Copyright:
© 2016 Elsevier Ltd
PY - 2016/7
Y1 - 2016/7
N2 - The luminescence and scintillation properties of YGd2Al2Ga3O12:Ce and LuGd2Al2Ga3O12:Ce single crystal scintillators were compared. The light yield (LY) and energy resolution were measured using R6231 photomultiplier. At 662 keV γ-rays, high LY value of 37,900 ph/MeV and energy resolution of 7.0% obtained for YGd2Al2Ga3O12:Ce are slightly better than the values of 35,400 ph/MeV and 7.6% obtained for LuGd2Al2Ga3O12:Ce. The ratio of LY values under excitation with α- and γ-rays (α/γ ratio) was also determined. The LY dependence on amplifier shaping time was measured in order to investigate the timing characteristics in the scintillation response. The estimated photofraction in pulse height spectrum of 662 keV γ-rays and the total mass attenuation coefficient at 662 keV γ-rays were also determined and compared with the theoretical ones calculated using the WinXCom program.
AB - The luminescence and scintillation properties of YGd2Al2Ga3O12:Ce and LuGd2Al2Ga3O12:Ce single crystal scintillators were compared. The light yield (LY) and energy resolution were measured using R6231 photomultiplier. At 662 keV γ-rays, high LY value of 37,900 ph/MeV and energy resolution of 7.0% obtained for YGd2Al2Ga3O12:Ce are slightly better than the values of 35,400 ph/MeV and 7.6% obtained for LuGd2Al2Ga3O12:Ce. The ratio of LY values under excitation with α- and γ-rays (α/γ ratio) was also determined. The LY dependence on amplifier shaping time was measured in order to investigate the timing characteristics in the scintillation response. The estimated photofraction in pulse height spectrum of 662 keV γ-rays and the total mass attenuation coefficient at 662 keV γ-rays were also determined and compared with the theoretical ones calculated using the WinXCom program.
KW - Light yield
KW - LuGdAlGaO:Ce
KW - Luminescence
KW - Scintillation
KW - YGdAlGaO:Ce
UR - http://www.scopus.com/inward/record.url?scp=84953455330&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84953455330&partnerID=8YFLogxK
U2 - 10.1016/j.radmeas.2015.12.036
DO - 10.1016/j.radmeas.2015.12.036
M3 - Article
AN - SCOPUS:84953455330
SN - 1350-4487
VL - 90
SP - 153
EP - 156
JO - Radiation Measurements
JF - Radiation Measurements
ER -