TY - GEN
T1 - Mechanical power of ankle plantar flexion and subjective pain by monophasic electrical stimulation
AU - Suzuki, Tatsuto
AU - Watanabe, Takashi
AU - Saura, Ryuichi
AU - Uchiyama, Hironobu
PY - 2011
Y1 - 2011
N2 - The aim of this study was to investigate the mechanical power of the ankle plantar flexion. The investigated power of the ankle plantar flexion would help to improve effectively the FES walking system using the ankle plantar flexion for patients and aged people in slow walking. The subjective pain by electrical stimulation sometimes becomes the burden to use the FES system. We also investigated the relationship between the mechanical power in ankle plantar flexion by electrical stimulation and the subjective pain. We developed the device to measure the ankle movement by electrical stimulation against load resistance torque. The device consisted of pads to support a single lower leg, a rotational footplate with a large pulley and a vertical weight to generate the load resistance torque, and a monophasic electrical stimulator via surface electrodes. Our results showed the proportional relationship between the mechanical power of the ankle plantar flexion and the subjective pain by electrical stimulation. To generate the same level in the ankle plantar flexor power 2.75W under the maximum voluntary exertion, the subjective pain by electrical stimulation exceeded 70, which means the feeling of crying at the Face Pain Scale. This result would help the better design of the FES walking system using the ankle plantar flexion for patients and aged people.
AB - The aim of this study was to investigate the mechanical power of the ankle plantar flexion. The investigated power of the ankle plantar flexion would help to improve effectively the FES walking system using the ankle plantar flexion for patients and aged people in slow walking. The subjective pain by electrical stimulation sometimes becomes the burden to use the FES system. We also investigated the relationship between the mechanical power in ankle plantar flexion by electrical stimulation and the subjective pain. We developed the device to measure the ankle movement by electrical stimulation against load resistance torque. The device consisted of pads to support a single lower leg, a rotational footplate with a large pulley and a vertical weight to generate the load resistance torque, and a monophasic electrical stimulator via surface electrodes. Our results showed the proportional relationship between the mechanical power of the ankle plantar flexion and the subjective pain by electrical stimulation. To generate the same level in the ankle plantar flexor power 2.75W under the maximum voluntary exertion, the subjective pain by electrical stimulation exceeded 70, which means the feeling of crying at the Face Pain Scale. This result would help the better design of the FES walking system using the ankle plantar flexion for patients and aged people.
UR - http://www.scopus.com/inward/record.url?scp=84864623464&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84864623464&partnerID=8YFLogxK
U2 - 10.1109/IEMBS.2011.6091828
DO - 10.1109/IEMBS.2011.6091828
M3 - Conference contribution
C2 - 22256008
AN - SCOPUS:84864623464
SN - 9781424441211
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 7234
EP - 7237
BT - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
T2 - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
Y2 - 30 August 2011 through 3 September 2011
ER -