Nondestructive evaluation of hardening degree of epoxy resin in CFRP with eddy current testing

Hiroyuki Kosukegawa, Rie Yamada, Shinya Tamonoki, Noriyuki Sato, Keisuke Ura, Toshiyuki Takagi

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

Chemiluminescence anlaysis and high-frequency eddy current testing (HF-ECT) were examined as nondestructive evaluation techniques to assess the hardening degree of epoxy resin in carbon fiber-reinforced plastic. Both techniques showed a correlation with the hardening degree of epoxy resin measured by differential scanning calorimetry. The results also indicated that the application of HF-ECT at frequencies of >50 MHz is suited for hardening degree determination.

Original languageEnglish
Title of host publicationElectromagnetic Non-Destructive Evaluation (XXI)
EditorsDominique Lesselier, Christophe Reboud
PublisherIOS Press
Pages65-72
Number of pages8
ISBN (Electronic)9781614998358
DOIs
Publication statusPublished - 2018
Event22nd International Workshop on Electromagnetic Nondestructive Evaluation, ENDE 2017 - Saclay, France
Duration: 2017 Sept 62017 Sept 8

Publication series

NameStudies in Applied Electromagnetics and Mechanics
Volume43
ISSN (Print)1383-7281
ISSN (Electronic)1879-8322

Other

Other22nd International Workshop on Electromagnetic Nondestructive Evaluation, ENDE 2017
Country/TerritoryFrance
CitySaclay
Period17/9/617/9/8

Keywords

  • CFRP
  • Chemiluminescence analysis
  • Differential scanning calorimetry
  • Hardening degree
  • High frequency eddy current testing

ASJC Scopus subject areas

  • Mechanical Engineering
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Nondestructive evaluation of hardening degree of epoxy resin in CFRP with eddy current testing'. Together they form a unique fingerprint.

Cite this