T1 - Noninvasive stroke volume variation using electrical velocimetry for predicting fluid responsiveness in dogs undergoing cardiac surgery
AU - Sasaki, Kazumasu
AU - Mutoh, Tatsushi
AU - Mutoh, Tomoko
AU - Taki, Yasuyuki
AU - Kawashima, Ryuta
N1 - Publisher Copyright:
© 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia
PY - 2017/7
Y1 - 2017/7
N2 - Objective To evaluate the ability of a noninvasive cardiac output monitoring system with electrical velocimetry (EV) for predicting fluid responsiveness in dogs undergoing cardiac surgery. Study design Prospective experimental trial. Animals A total of 30 adult Beagle dogs. Methods Stroke volume (SV), stroke volume variation (SVV) and cardiac index were measured using the EV device in sevoflurane-anaesthetized, mechanically ventilated dogs undergoing thoracotomies for experimental creation of right ventricular failure. The dogs were considered fluid responsive if stroke volume (SVI; indexed to body weight), measured using pulmonary artery thermodilution, increased by 10% or more after volume loading (10 mL kg–1). Relationships of SVV, central venous pressure (CVP) and pulmonary artery occlusion pressure (PAOP) with SVI were analysed to estimate fluid responsiveness. Results Better prediction of fluid responsiveness, with a significant area under the receiver operating characteristic curve, was observed for SVV (0.85 ± 0.07; p = 0.0016) in comparison with CVP (0.65 ± 0.11; p = 0.17) or PAOP (0.60 ± 0.12; p = 0.35), with a cut-off value of 13.5% (84% specificity and 73% sensitivity). Conclusions and clinical relevance SVV derived from EV is useful for identification of dogs that are likely to respond to fluids, providing valuable information on volume status under cardiothoracic anaesthesia.
AB - Objective To evaluate the ability of a noninvasive cardiac output monitoring system with electrical velocimetry (EV) for predicting fluid responsiveness in dogs undergoing cardiac surgery. Study design Prospective experimental trial. Animals A total of 30 adult Beagle dogs. Methods Stroke volume (SV), stroke volume variation (SVV) and cardiac index were measured using the EV device in sevoflurane-anaesthetized, mechanically ventilated dogs undergoing thoracotomies for experimental creation of right ventricular failure. The dogs were considered fluid responsive if stroke volume (SVI; indexed to body weight), measured using pulmonary artery thermodilution, increased by 10% or more after volume loading (10 mL kg–1). Relationships of SVV, central venous pressure (CVP) and pulmonary artery occlusion pressure (PAOP) with SVI were analysed to estimate fluid responsiveness. Results Better prediction of fluid responsiveness, with a significant area under the receiver operating characteristic curve, was observed for SVV (0.85 ± 0.07; p = 0.0016) in comparison with CVP (0.65 ± 0.11; p = 0.17) or PAOP (0.60 ± 0.12; p = 0.35), with a cut-off value of 13.5% (84% specificity and 73% sensitivity). Conclusions and clinical relevance SVV derived from EV is useful for identification of dogs that are likely to respond to fluids, providing valuable information on volume status under cardiothoracic anaesthesia.
KW - cardiac surgery
KW - dog
KW - electrical velocimetry
KW - fluid therapy
KW - haemodynamic monitoring
UR - http://www.scopus.com/inward/record.url?scp=85031118241&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85031118241&partnerID=8YFLogxK
U2 - 10.1016/j.vaa.2016.11.001
DO - 10.1016/j.vaa.2016.11.001
M3 - Article
C2 - 28803717
AN - SCOPUS:85031118241
SN - 1467-2987
VL - 44
SP - 719
EP - 726
JO - Veterinary Anaesthesia and Analgesia
JF - Veterinary Anaesthesia and Analgesia
IS - 4
ER -