TY - JOUR
T1 - Performance of TOF-RPC for the BGOegg experiment
AU - Tomida, N.
AU - Tran, N.
AU - Niiyama, M.
AU - Ohnishi, H.
AU - Muramatsu, N.
N1 - Publisher Copyright:
© 2016 IOP Publishing Ltd and Sissa Medialab srl.
PY - 2016/11/28
Y1 - 2016/11/28
N2 - We constructed a new time-of-flight (TOF) detector consisting of resistive plate chambers (RPCs) to measure particle energy in the BGOegg experiment. The BGOegg-RPC has a unique feature which enables us to cover a large area with a small number of readout channels. For this purpose, we developed the RPC with a strip size of 2.5 cm × 100 cm. The BGOegg-RPC covers an area of 320 cm × 200 cm with only 256 channels of readout electronics. In case of large readout RPCs, an originated signal is distorted and dispersed during propagation. In addition, there happens a signal reflection at the end of the strip. Although we designed the BGOegg-RPC and front-end electronics with minimized signal reflection, a small reflection still remained, deteriorating the resulting time resolution. After establishing calibration and correction methods to improve the performance of the BGOegg-RPC, we obtained the time resolution of σ ∼ 60 ps around the central region of strips.
AB - We constructed a new time-of-flight (TOF) detector consisting of resistive plate chambers (RPCs) to measure particle energy in the BGOegg experiment. The BGOegg-RPC has a unique feature which enables us to cover a large area with a small number of readout channels. For this purpose, we developed the RPC with a strip size of 2.5 cm × 100 cm. The BGOegg-RPC covers an area of 320 cm × 200 cm with only 256 channels of readout electronics. In case of large readout RPCs, an originated signal is distorted and dispersed during propagation. In addition, there happens a signal reflection at the end of the strip. Although we designed the BGOegg-RPC and front-end electronics with minimized signal reflection, a small reflection still remained, deteriorating the resulting time resolution. After establishing calibration and correction methods to improve the performance of the BGOegg-RPC, we obtained the time resolution of σ ∼ 60 ps around the central region of strips.
KW - Instrumentation and methods for time-of-flight (TOF) spectroscopy
KW - Resistive-plate chambers
KW - Timing detectors
UR - http://www.scopus.com/inward/record.url?scp=85000910709&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85000910709&partnerID=8YFLogxK
U2 - 10.1088/1748-0221/11/11/C11037
DO - 10.1088/1748-0221/11/11/C11037
M3 - Article
AN - SCOPUS:85000910709
SN - 1748-0221
VL - 11
JO - Journal of Instrumentation
JF - Journal of Instrumentation
IS - 11
M1 - C11037
ER -