TY - JOUR
T1 - Possible utility of contrast-enhanced ultrasonography for detecting spread of local anesthetic in nerve block
AU - Sasaki, Hideaki
AU - Yamauchi, Masanori
AU - Ninomiya, Takafumi
AU - Tatsumi, Haruyuki
AU - Yamakage, Michiaki
N1 - Funding Information:
We wish to thank to Professor Mineko Fujimiya (Department of Anatomy, Sapporo Medical University School of Medicine) for the preparation of Thiel-embalmed cadavers, and Tomohisa Niiya, Takeshi Murouchi, Eri Gi and Syunsuke Hayashi (Department of Anaesthesiology, Sapporo Medical University School of Medicine) for their excellent assistance. This work was supported by the Japan Society for the Promotion of Science KAKENHI Grant-in-Aid (Numbers: 25861388, 24592350).
Publisher Copyright:
© 2017, Japanese Society of Anesthesiologists.
PY - 2017/6/1
Y1 - 2017/6/1
N2 - Purpose: This study demonstrated the effects of perfluorobutane (Sonazoid®) with contrast-enhanced ultrasonography (CEUS) to identify the spread of local anesthetics in ultrasound-guided nerve block. Methods: This study consists of simulation, cadaveric, and animal studies. In a simulation study, 1% lidocaine with 10- to 1000-fold diluted Sonazoid®, a US-specific contrast agent to diagnose hepatic and breast cancers (0.5 mL), was injected into a resin-based phantom to determine the optimal concentration for ultrasound-guided peripheral nerve block. The enhanced area was measured by direct observation and ultrasonography (US). In the cadaver study, ultrasound-guided sciatic nerve block was performed at the popliteal fossa in the 9 extremities, and 5 mL of the optimally diluted Sonazoid® defined in the simulation study with X-ray contrast medium and blue dye was injected. Longitudinal spread of the solution was measured by CEUS, X-ray imaging and anatomical dissection. In the animal study, the optimally diluted Sonazoid® was injected around the sciatic nerve of rats (n = 6), and neuronal function and toxicity were evaluated by behavioral and histological estimation. Results: The simulation study proved that 100-fold diluted Sonazoid® was the optimal concentration. In the cadaver study, CEUS and anatomical dissection (r = 0.90, P = 0.0020) or radiography (r = 0.84, P = 0.0072) showed high agreement and correlation with the longitudinal spread. CEUS clearly showed a fine intraneuronal injection image compared to the usual B-mode imaging. The animal study suggested no adverse effects by co-administration of lidocaine and Sonazoid®. Conclusions: CEUS with 100-fold diluted Sonazoid® could identify the spread of local anesthetic as well as radiography and anatomical dissection, and distinguish between intra- and extraneuronal injections without neurodegeneration.
AB - Purpose: This study demonstrated the effects of perfluorobutane (Sonazoid®) with contrast-enhanced ultrasonography (CEUS) to identify the spread of local anesthetics in ultrasound-guided nerve block. Methods: This study consists of simulation, cadaveric, and animal studies. In a simulation study, 1% lidocaine with 10- to 1000-fold diluted Sonazoid®, a US-specific contrast agent to diagnose hepatic and breast cancers (0.5 mL), was injected into a resin-based phantom to determine the optimal concentration for ultrasound-guided peripheral nerve block. The enhanced area was measured by direct observation and ultrasonography (US). In the cadaver study, ultrasound-guided sciatic nerve block was performed at the popliteal fossa in the 9 extremities, and 5 mL of the optimally diluted Sonazoid® defined in the simulation study with X-ray contrast medium and blue dye was injected. Longitudinal spread of the solution was measured by CEUS, X-ray imaging and anatomical dissection. In the animal study, the optimally diluted Sonazoid® was injected around the sciatic nerve of rats (n = 6), and neuronal function and toxicity were evaluated by behavioral and histological estimation. Results: The simulation study proved that 100-fold diluted Sonazoid® was the optimal concentration. In the cadaver study, CEUS and anatomical dissection (r = 0.90, P = 0.0020) or radiography (r = 0.84, P = 0.0072) showed high agreement and correlation with the longitudinal spread. CEUS clearly showed a fine intraneuronal injection image compared to the usual B-mode imaging. The animal study suggested no adverse effects by co-administration of lidocaine and Sonazoid®. Conclusions: CEUS with 100-fold diluted Sonazoid® could identify the spread of local anesthetic as well as radiography and anatomical dissection, and distinguish between intra- and extraneuronal injections without neurodegeneration.
KW - Cadaver
KW - Contrast medium
KW - Nerve block
KW - Perfluorobutane
KW - Ultrasonography
UR - http://www.scopus.com/inward/record.url?scp=85016990408&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85016990408&partnerID=8YFLogxK
U2 - 10.1007/s00540-017-2347-x
DO - 10.1007/s00540-017-2347-x
M3 - Article
C2 - 28374060
AN - SCOPUS:85016990408
SN - 0913-8668
VL - 31
SP - 365
EP - 373
JO - Journal of Anesthesia
JF - Journal of Anesthesia
IS - 3
ER -