TY - JOUR
T1 - Practical method to determine the effective zero-point of indentation depth for continuous stiffness measurement nanoindentation test with Berkovich tip
AU - Geng, Diancheng
AU - Yu, Hao
AU - Okuno, Yasuki
AU - Kondo, Sosuke
AU - Kasada, Ryuta
N1 - Funding Information:
This study was supported by the Japan Society for the Promotion of Science (JSPS) KAKENHI program (grant number 19H02643).
Publisher Copyright:
© 2022, The Author(s).
PY - 2022/12
Y1 - 2022/12
N2 - The zero-point of indentation depth in nanoindentation or depth-sensing instrumented indentation tests should be precisely set to evaluate the indentation hardness and indentation elastic modulus of materials to be tested, especially at shallow depths. A critical contact stiffness value has been widely used to determine the zero-point in nanoindentation tests with a Berkovich tip using the continuous stiffness measurement (CSM) method. However, this criterion occasionally gives an inadequate zero-point owing to the surface roughness of materials, the vibration of the testing system, and the flaws of the CSM method at shallow depth. This study proposes a practical method to determine the effective zero-point of indentation depth, which was obtained linearly at the zero-point of contact stiffness and extrapolated from the depth-dependent contact stiffness values, except for those at initially unstable contact depths. The proposed method enables nanoindentation tests to obtain a constant indentation elastic modulus and low deviation of nanoindentation hardness of homogenously fused silica and metallic materials, which provides an efficient way to obtain more accurate test data.
AB - The zero-point of indentation depth in nanoindentation or depth-sensing instrumented indentation tests should be precisely set to evaluate the indentation hardness and indentation elastic modulus of materials to be tested, especially at shallow depths. A critical contact stiffness value has been widely used to determine the zero-point in nanoindentation tests with a Berkovich tip using the continuous stiffness measurement (CSM) method. However, this criterion occasionally gives an inadequate zero-point owing to the surface roughness of materials, the vibration of the testing system, and the flaws of the CSM method at shallow depth. This study proposes a practical method to determine the effective zero-point of indentation depth, which was obtained linearly at the zero-point of contact stiffness and extrapolated from the depth-dependent contact stiffness values, except for those at initially unstable contact depths. The proposed method enables nanoindentation tests to obtain a constant indentation elastic modulus and low deviation of nanoindentation hardness of homogenously fused silica and metallic materials, which provides an efficient way to obtain more accurate test data.
UR - http://www.scopus.com/inward/record.url?scp=85128313533&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85128313533&partnerID=8YFLogxK
U2 - 10.1038/s41598-022-10490-8
DO - 10.1038/s41598-022-10490-8
M3 - Article
C2 - 35430627
AN - SCOPUS:85128313533
SN - 2045-2322
VL - 12
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 6391
ER -