TY - JOUR
T1 - Preheating temperature effect on tritium retention in VPS-W
AU - Sato, Misaki
AU - Uchimura, Hiromichi
AU - Toda, Kensuke
AU - Tokunaga, Tomonori
AU - Watanabe, Hideo
AU - Yoshida, Naoaki
AU - Hatano, Yuji
AU - Kasada, Ryuta
AU - Nagasaka, Takuya
AU - Kimura, Akihiko
AU - Oya, Yasuhisa
AU - Okuno, Kenji
N1 - Publisher Copyright:
© 2015, American Nuclear Society. All rights reserved.
PY - 2015/4/1
Y1 - 2015/4/1
N2 - The deuterium retention behavior for the Vacuum Plasma Spraying (VPS) tungsten (W) coating was studied to demonstrate the tritium retention as a function of heating temperature. It was found that two major deuterium desorption stages were observed at the temperature regions of 400 - 700 K (Stage 1) and 900 - 1100 K (Stage 2), considering that Stage 1 was linked to the desorption of deuterium trapped by near surface and intrinsic defects, and Stage 2 was related to the desorption of deuterium bound to impurities as C-D bonds. By heating the sample above 673 K, the major peak of C-1s was shifted from C-O bond to C-C bond, where the retention of deuterium as Stage 2 was increased. Therefore it was indicating that the hydrogen isotope retention was controlled by the amount of C-C bond in VPS, most of which was contaminated during the VPS coating process. The comparison of several samples (VPS-W with shading, VPS-W without shading and Polycrystalline W (PCW)) shows that the carbon impurity has a large affinity with deuterium and make stable trapping states compared to that with intrinsic defects and grain boundaries. However, most of them was reduced by heating at 1173 K. Therefore, heating treatment is quite important to get rid of carbon impurities and refrain higher tritium retention in VPS.
AB - The deuterium retention behavior for the Vacuum Plasma Spraying (VPS) tungsten (W) coating was studied to demonstrate the tritium retention as a function of heating temperature. It was found that two major deuterium desorption stages were observed at the temperature regions of 400 - 700 K (Stage 1) and 900 - 1100 K (Stage 2), considering that Stage 1 was linked to the desorption of deuterium trapped by near surface and intrinsic defects, and Stage 2 was related to the desorption of deuterium bound to impurities as C-D bonds. By heating the sample above 673 K, the major peak of C-1s was shifted from C-O bond to C-C bond, where the retention of deuterium as Stage 2 was increased. Therefore it was indicating that the hydrogen isotope retention was controlled by the amount of C-C bond in VPS, most of which was contaminated during the VPS coating process. The comparison of several samples (VPS-W with shading, VPS-W without shading and Polycrystalline W (PCW)) shows that the carbon impurity has a large affinity with deuterium and make stable trapping states compared to that with intrinsic defects and grain boundaries. However, most of them was reduced by heating at 1173 K. Therefore, heating treatment is quite important to get rid of carbon impurities and refrain higher tritium retention in VPS.
UR - http://www.scopus.com/inward/record.url?scp=84928171479&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84928171479&partnerID=8YFLogxK
U2 - 10.13182/FST14-T77
DO - 10.13182/FST14-T77
M3 - Article
AN - SCOPUS:84928171479
SN - 1536-1055
VL - 67
SP - 551
EP - 554
JO - Fusion Science and Technology
JF - Fusion Science and Technology
IS - 3
ER -