TY - JOUR
T1 - Quantification of regional myocardial oxygen metabolism in normal pigs using positron emission tomography with injectable 15O-O2
AU - Temma, Takashi
AU - Iida, Hidehiro
AU - Hayashi, Takuya
AU - Teramoto, Noboru
AU - Ohta, Youichiro
AU - Kudomi, Nobuyuki
AU - Watabe, Hiroshi
AU - Saji, Hideo
AU - Magata, Yasuhiro
PY - 2010/2
Y1 - 2010/2
N2 - Purpose: Although 15O-O2 gas inhalation can provide a reliable and accurate myocardial metabolic rate for oxygen by PET, the spillover from gas volume in the lung distorts the images. Recently, we developed an injectable method in which blood takes up 15O-O 2 from an artificial lung, and this made it possible to estimate oxygen metabolism without the inhalation protocol. In the present study, we evaluated the effectiveness of the injectable 15O-O2 system in porcine hearts. Methods: PET scans were performed after bolus injection and continuous infusion of injectable 15O-O2 via a shunt between the femoral artery and the vein in normal pigs. The injection method was compared to the inhalation method. The oxygen extraction fraction (OEF) in the lateral walls of the heart was calculated by a compartmental model in view of the spillover and partial volume effect. Results: A significant decrease of lung radioactivity in PET images was observed compared to the continuous inhalation of 15O-O2 gas. Furthermore, the injectable 15O-O2 system provides a measurement of OEF in lateral walls of the heart that is similar to the continuous-inhalation method (0.71±0.036 and 0.72±0.020 for the bolus-injection and continuous-infusion methods, respectively). Conclusion: These results indicate that injectable 15O-O2 has the potential to evaluate myocardial oxygen metabolism.
AB - Purpose: Although 15O-O2 gas inhalation can provide a reliable and accurate myocardial metabolic rate for oxygen by PET, the spillover from gas volume in the lung distorts the images. Recently, we developed an injectable method in which blood takes up 15O-O 2 from an artificial lung, and this made it possible to estimate oxygen metabolism without the inhalation protocol. In the present study, we evaluated the effectiveness of the injectable 15O-O2 system in porcine hearts. Methods: PET scans were performed after bolus injection and continuous infusion of injectable 15O-O2 via a shunt between the femoral artery and the vein in normal pigs. The injection method was compared to the inhalation method. The oxygen extraction fraction (OEF) in the lateral walls of the heart was calculated by a compartmental model in view of the spillover and partial volume effect. Results: A significant decrease of lung radioactivity in PET images was observed compared to the continuous inhalation of 15O-O2 gas. Furthermore, the injectable 15O-O2 system provides a measurement of OEF in lateral walls of the heart that is similar to the continuous-inhalation method (0.71±0.036 and 0.72±0.020 for the bolus-injection and continuous-infusion methods, respectively). Conclusion: These results indicate that injectable 15O-O2 has the potential to evaluate myocardial oxygen metabolism.
KW - Injectable O-O
KW - Myocardial oxygen metabolism
KW - OEF
KW - PET
KW - Pig
UR - http://www.scopus.com/inward/record.url?scp=77949270277&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77949270277&partnerID=8YFLogxK
U2 - 10.1007/s00259-009-1262-2
DO - 10.1007/s00259-009-1262-2
M3 - Article
C2 - 19760412
AN - SCOPUS:77949270277
SN - 1619-7070
VL - 37
SP - 377
EP - 385
JO - European Journal of Nuclear Medicine and Molecular Imaging
JF - European Journal of Nuclear Medicine and Molecular Imaging
IS - 2
ER -