TY - JOUR
T1 - Quantitative diagnostic imaging of cancer tissues by using phosphor-integrated dots with ultra-high brightness
AU - Gonda, Kohsuke
AU - Watanabe, Mika
AU - Tada, Hiroshi
AU - Miyashita, Minoru
AU - Takahashi-Aoyama, Yayoi
AU - Kamei, Takashi
AU - Ishida, Takanori
AU - Usami, Shin
AU - Hirakawa, Hisashi
AU - Kakugawa, Yoichiro
AU - Hamanaka, Yohei
AU - Yoshida, Ryuichi
AU - Furuta, Akihiko
AU - Okada, Hisatake
AU - Goda, Hideki
AU - Negishi, Hiroshi
AU - Takanashi, Kensaku
AU - Takahashi, Masaru
AU - Ozaki, Yuichi
AU - Yoshihara, Yuka
AU - Nakano, Yasushi
AU - Ohuchi, Noriaki
N1 - Publisher Copyright:
© 2017 The Author(s).
PY - 2017/12/1
Y1 - 2017/12/1
N2 - The quantitative sensitivity and dynamic range of conventional immunohistochemistry (IHC) with 3,3′-diaminobenzidine (IHC-DAB) used in pathological diagnosis in hospitals are poor, because enzyme activity can affect the IHC-DAB chromogenic reaction. Although fluorescent IHC can effectively increase the quantitative sensitivity of conventional IHC, tissue autofluorescence interferes with the sensitivity. Here, we created new fluorescent nanoparticles called phosphor-integrated dots (PIDs). PIDs have 100-fold greater brightness and a more than 300-fold greater dynamic range than those of commercially available fluorescent nanoparticles, quantum dots, whose fluorescence intensity is comparable to tissue autofluorescence. Additionally, a newly developed image-processing method enabled the calculation of the PID particle number in the obtained image. To quantify the sensitivity of IHC using PIDs (IHC-PIDs), the IHC-PIDs method was compared with fluorescence-activated cell sorting (FACS), a method well suited for evaluating total protein amount, and the two values exhibited strong correlation (R = 0.94). We next applied IHC-PIDs to categorize the response to molecular target-based drug therapy in breast cancer patients. The results suggested that the PID particle number estimated by IHC-PIDs of breast cancer tissues obtained from biopsy before chemotherapy can provide a score for predicting the therapeutic effect of the human epidermal growth factor receptor 2-targeted drug trastuzumab.
AB - The quantitative sensitivity and dynamic range of conventional immunohistochemistry (IHC) with 3,3′-diaminobenzidine (IHC-DAB) used in pathological diagnosis in hospitals are poor, because enzyme activity can affect the IHC-DAB chromogenic reaction. Although fluorescent IHC can effectively increase the quantitative sensitivity of conventional IHC, tissue autofluorescence interferes with the sensitivity. Here, we created new fluorescent nanoparticles called phosphor-integrated dots (PIDs). PIDs have 100-fold greater brightness and a more than 300-fold greater dynamic range than those of commercially available fluorescent nanoparticles, quantum dots, whose fluorescence intensity is comparable to tissue autofluorescence. Additionally, a newly developed image-processing method enabled the calculation of the PID particle number in the obtained image. To quantify the sensitivity of IHC using PIDs (IHC-PIDs), the IHC-PIDs method was compared with fluorescence-activated cell sorting (FACS), a method well suited for evaluating total protein amount, and the two values exhibited strong correlation (R = 0.94). We next applied IHC-PIDs to categorize the response to molecular target-based drug therapy in breast cancer patients. The results suggested that the PID particle number estimated by IHC-PIDs of breast cancer tissues obtained from biopsy before chemotherapy can provide a score for predicting the therapeutic effect of the human epidermal growth factor receptor 2-targeted drug trastuzumab.
UR - http://www.scopus.com/inward/record.url?scp=85027032997&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85027032997&partnerID=8YFLogxK
U2 - 10.1038/s41598-017-06534-z
DO - 10.1038/s41598-017-06534-z
M3 - Article
C2 - 28790306
AN - SCOPUS:85027032997
SN - 2045-2322
VL - 7
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 7509
ER -