Radiation dose of interventional radiology system using a flat-panel detector

Koichi Chida, Yohei Inaba, Haruo Saito, Tadashi Ishibashi, Syouki Takahashi, Masahiro Kozuki, Masayuki Zuguchi

Research output: Contribution to journalArticlepeer-review

70 Citations (Scopus)

Abstract

OBJECTIVE. Currently, cardiac interventional radiology equipment has tended toward using flat-panel detectors (FPDs) instead of image intensifiers (IIs) because FPDs offer better imaging performance. However, the radiation dose from an FPD in cardiac interventional radiology is not clear. The purpose of our study was to measure the radiation doses during cineangiography and fluoroscopy of many cardiac radiology systems that use FPDs or IIs, in clinical settings. MATERIALS AND METHODS. This study examined 20 radiology systems in 15 cardiac catheterization laboratories (11 used FPD and nine used II). The entrance surface doses with digital cineangiography and fluoroscopy were compared for the 20 systems using acrylic plates (20-cm thick) and a skin dose monitor. RESULTS. For fluoroscopy, the average entrance surface doses of the 20-cm-thick acrylic plates were identical for FPD (average ± SD, 16.63 ± 7.89 mGy/min; range, 5.7-26.4 mGy/ min; maximum/minimum, 4.63) and II (17.81 ± 12.52 mGy/min; range, 6.5-42.2 mGy/min; maximum/minimum, 6.49) (p = 0.799). For digital cineangiography, the average entrance surface dose of the 20-cm-thick acrylic plate was slightly lower with FPD (29.68 ± 16.40 mGy/10 s; range, 8.9-58.5 mGy/10 s; maximum/minimum, 6.57) than with II (38.50 ± 33.71 mGy/10 s; range, 15.2-117.1 mGy/10 s; maximum/minimum, 7.70), although the difference was not significant (p = 0.487). CONCLUSION. We found that the average entrance doses of cineangiography and fluoroscopy in FPD systems were not significantly different from those in II systems. Hence, FPDs did not inherently reduce the radiation dose, although FPDs possess good detective quantum efficiency. Therefore, to reduce the radiation dose of cardiac interventional radiology systems, even FPD systems, practical measures are necessary.

Original languageEnglish
Pages (from-to)1680-1685
Number of pages6
JournalAmerican Journal of Roentgenology
Volume193
Issue number6
DOIs
Publication statusPublished - 2009 Dec

Keywords

  • Flat-panel detector
  • Fluoroscopy
  • Interventional radiology
  • Percutaneous coronary intervention
  • Radiation dose

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging