Abstract
We have studied for upgrading an 18 T super-conducting magnet conductively cooled by a GM/JT cryocooler at Tohoku University in Japan to a 23 T superconducting magnet. In order to upgrade the cryogen-free high field superconducting magnet up to 23 T, YBa 2}Cu 3O 7(Y123)coated conductor insert is intended for replacing the insert using Bi 2Sr 2Ca 2}Cu 3}O 10}({Bi2223) tape with stainless steel reinforcement tape. We have produced double pancake coils with almost the same size as a double pancake coil for the Bi2223 insert, and have investigated the performance of the coils. And the design of the double pancake coil was reviewed from the result of the R&D coils.
Original language | English |
---|---|
Article number | 6101599 |
Journal | IEEE Transactions on Applied Superconductivity |
Volume | 22 |
Issue number | 3 |
DOIs | |
Publication status | Published - 2012 Jun 25 |
Keywords
- Degradation
- YBCO coated conductor
- high magnetic field
- radial tensile stress
ASJC Scopus subject areas
- Electronic, Optical and Magnetic Materials
- Condensed Matter Physics
- Electrical and Electronic Engineering