Sinogram-based Motion Correction of PET Images using Optical Motion Tracking System and List-mode Data Acquisition

Sang Keun Woo, Hiroshi Watabe, Yong Choi, Kyeong Min Kim, Chang Choon Park, Hidehiro Iida

Research output: Contribution to conferencePaperpeer-review

3 Citations (Scopus)

Abstract

A head motion during brain imaging has been recognized as a source of image degradation and introduces distortion in Positron Emission Tomography (PET) image. There are several techniques to correct the motion artifact, but these techniques cannot correct the motion during scanning. The aim of this study is to develop a sinogram-based motion correction (SBMC) method to correct directly the head motion during PET scanning using a motion tracking system and list-mode data acquisition. This method is a rebinning procedure by which the lines of response (LOR) are geometrically transformed according to the current values of the six-dimensional motion data. Michelogram was recomposed using rebinned LOR and motion corrected sinogram was generated. In the motion corrected image, the blurring artifact due to motion was reduced by SBMC method. This method was applicable to real PET data acquired with list-mode and shows a potential for real-time motion correction of head motion during PET scanning.

Original languageEnglish
Pages830-834
Number of pages5
Publication statusPublished - 2002
Externally publishedYes
Event2002 IEEE Nuclear Science Symposium Conference Record - Norfolk, VA, United States
Duration: 2002 Nov 102002 Nov 16

Other

Other2002 IEEE Nuclear Science Symposium Conference Record
Country/TerritoryUnited States
CityNorfolk, VA
Period02/11/1002/11/16

ASJC Scopus subject areas

  • Radiation
  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Sinogram-based Motion Correction of PET Images using Optical Motion Tracking System and List-mode Data Acquisition'. Together they form a unique fingerprint.

Cite this