T1 - Stability of electron-beam energy monitor for quality assurance of the electron-beam energy from radiotherapy accelerators
AU - Chida, Koichi
AU - Saito, Haruo
AU - Takai, Yoshihiro
AU - Zuguchi, Masayuki
AU - Mitsuya, Masatoshi
AU - Sakakida, Hideharu
AU - Kohzuki, Masahiro
AU - Yamada, Shogo
PY - 2002/11/1
Y1 - 2002/11/1
N2 - Information on electron energy is important in planning radiation therapy using electrons. The Geske 3405 electron beam energy monitor (Geske monitor, PTW Nuclear Associates, Carle Place, NY, USA) is a device containing nine ionization chambers for checking the energy of the electron beams produced by radiotherapy accelerators. We wondered whether this might increase the likelihood of ionization chamber trouble. In spite of the importance of the stability of such a quality assurance (QA) device, there are no reports on the stability of values measured with a Geske monitor. The purpose of this paper was therefore to describe the stability of a Geske monitor. It was found that the largest coefficient of variation (CV) of the Geske monitor measurements was approximately 0.96% over a 21-week period. In conclusion, the stability of Geske monitor measurements of the energy of electron beams from a linear accelerator was excellent.
AB - Information on electron energy is important in planning radiation therapy using electrons. The Geske 3405 electron beam energy monitor (Geske monitor, PTW Nuclear Associates, Carle Place, NY, USA) is a device containing nine ionization chambers for checking the energy of the electron beams produced by radiotherapy accelerators. We wondered whether this might increase the likelihood of ionization chamber trouble. In spite of the importance of the stability of such a quality assurance (QA) device, there are no reports on the stability of values measured with a Geske monitor. The purpose of this paper was therefore to describe the stability of a Geske monitor. It was found that the largest coefficient of variation (CV) of the Geske monitor measurements was approximately 0.96% over a 21-week period. In conclusion, the stability of Geske monitor measurements of the energy of electron beams from a linear accelerator was excellent.
KW - Electron beam energy monitoring
KW - Electron therapy
KW - Quality assurance
KW - Radiation therapy
UR - http://www.scopus.com/inward/record.url?scp=12244310473&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=12244310473&partnerID=8YFLogxK
U2 - 10.1620/tjem.198.197
DO - 10.1620/tjem.198.197
M3 - Article
C2 - 12597247
AN - SCOPUS:12244310473
SN - 0040-8727
VL - 198
SP - 197
EP - 201
JO - Tohoku Journal of Experimental Medicine
JF - Tohoku Journal of Experimental Medicine
IS - 3
ER -