TY - JOUR
T1 - Study on detection algorithm of fatal arrhythmia using multiple regression analysis
AU - Abe, Makoto
AU - Sugai, Telma Keiko
AU - Yoshizawa, Makoto
AU - Yambe, Tomoyuki
AU - Shimizu, Kazuo
AU - Goto, Moe
AU - Inagaki, Masashi
AU - Sugimachi, Masaru
AU - Sunagawa, Kenji
PY - 2010
Y1 - 2010
N2 - The implantable cardioverter-defibrillator (ICD) is an effective therapeutic device for rescuing patients with cardiac diseases from death caused by life-threatening arrhythmias. For development of the ICD, it is important to accurately distinguish among normal sinus rhythm, ventricular tachycardia (VT), ventricular fibrillation, and supraventricular tachycardia (SVT). Thus, in this study, we have proposed a multiple regression model based on 14 indices extracted from two-dimensional statistics of intracardiac electrocardiograms to detect four kinds of cardiac rhythms as accurately and quickly as possible. The experimental results showed that the proposed method had a sensitivity of 0.97 for detecting SVT and a specificity of 0.99 for detecting VT, which were improved respectively from 0.83 and 0.85 obtained from the previous method, and that early detection within about 1.6 seconds was attained.
AB - The implantable cardioverter-defibrillator (ICD) is an effective therapeutic device for rescuing patients with cardiac diseases from death caused by life-threatening arrhythmias. For development of the ICD, it is important to accurately distinguish among normal sinus rhythm, ventricular tachycardia (VT), ventricular fibrillation, and supraventricular tachycardia (SVT). Thus, in this study, we have proposed a multiple regression model based on 14 indices extracted from two-dimensional statistics of intracardiac electrocardiograms to detect four kinds of cardiac rhythms as accurately and quickly as possible. The experimental results showed that the proposed method had a sensitivity of 0.97 for detecting SVT and a specificity of 0.99 for detecting VT, which were improved respectively from 0.83 and 0.85 obtained from the previous method, and that early detection within about 1.6 seconds was attained.
KW - Arrhythmia
KW - Implantable cardioverter-defibrillator
KW - Intracardiac electrocardiogram
KW - Multiple regression model
UR - http://www.scopus.com/inward/record.url?scp=79958863779&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79958863779&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:79958863779
SN - 1881-4379
VL - 48
SP - 577
EP - 583
JO - Transactions of Japanese Society for Medical and Biological Engineering
JF - Transactions of Japanese Society for Medical and Biological Engineering
IS - 6
ER -