TY - JOUR
T1 - [Study on the development of a patient dosimetry gown for interventional cardiology procedures].
AU - Kato, Mamoru
AU - Chida, Koichi
AU - Moritake, Takashi
AU - Koguchi, Yasuhiro
AU - Kaga, Yuji
AU - Sakamoto, Hajime
AU - Tsukamoto, Atsuko
AU - Kawauchi, Satoru
AU - Matsumoto, Kazuma
AU - Matsumura, Mitsuaki
AU - Oosaka, Hajime
AU - Tosa, Tetsuo
PY - 2014/8
Y1 - 2014/8
N2 - In recent years, dose justification and optimization have been attempted in percutaneous coronary intervention (PCI); however, deterministic effects have been reported. To prevent radiation skin injuries in PCI, it is necessary to measure the patient entrance skin dose (ESD), but an accurate dose measurement method has not yet been established. In this study, we developed a dosimetry gown that can measure the ESD during PCI using multiple radiophotoluminescence dosimeters (RPLDs). The RPLDs were placed into 84 pockets that were sewn into a dosimetry gown. Patients wear the original dosimetry gown during the procedures, after which we obtain accurate ESD measurements. We believe that this method using RPLDs and a newly-designed dosimetry gown provides accurate ESD measurements during PCI. We expect this system to become a standard method for measuring ESD during PCI.
AB - In recent years, dose justification and optimization have been attempted in percutaneous coronary intervention (PCI); however, deterministic effects have been reported. To prevent radiation skin injuries in PCI, it is necessary to measure the patient entrance skin dose (ESD), but an accurate dose measurement method has not yet been established. In this study, we developed a dosimetry gown that can measure the ESD during PCI using multiple radiophotoluminescence dosimeters (RPLDs). The RPLDs were placed into 84 pockets that were sewn into a dosimetry gown. Patients wear the original dosimetry gown during the procedures, after which we obtain accurate ESD measurements. We believe that this method using RPLDs and a newly-designed dosimetry gown provides accurate ESD measurements during PCI. We expect this system to become a standard method for measuring ESD during PCI.
UR - http://www.scopus.com/inward/record.url?scp=84907878642&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84907878642&partnerID=8YFLogxK
U2 - 10.6009/jjrt.2014_JSRT_70.8.814
DO - 10.6009/jjrt.2014_JSRT_70.8.814
M3 - Article
C2 - 25142393
AN - SCOPUS:84907878642
SN - 0369-4305
VL - 70
SP - 814
EP - 820
JO - Nihon Hoshasen Gijutsu Gakkai zasshi
JF - Nihon Hoshasen Gijutsu Gakkai zasshi
IS - 8
ER -