SU-8-based flexible amperometric device with IDA electrodes to regenerate redox species in small spaces

Yusuke Kanno, Takehito Goto, Kosuke Ino, Kumi Y. Inoue, Yasufumi Takahashi, Hitoshi Shiku, Tomokazu Matsue

Research output: Contribution to journalComment/debate

11 Citations (Scopus)

Abstract

A flexible sensor based on SU-8 photoresist was fabricated and its electrochemical performance was investigated using cyclic voltammetry. The device consisted of interdigitated array (IDA) electrodes on an SU-8 layer. It exhibited a clear electrochemical response during redox cycling of ferrocenemethanol at the IDA electrodes. Since the device was flexible, it could be inserted into a narrow bent space to monitor electrochemical responses. The observed electrochemical behavior was found to be consistent with that predicted by simulations based on redox compound diffusion.

Original languageEnglish
Pages (from-to)305-309
Number of pages5
JournalAnalytical Sciences
Volume30
Issue number2
DOIs
Publication statusPublished - 2014 Feb

Keywords

  • Amperometric sensor
  • Electrochemical detection
  • Flexible device
  • Interdigitated array (IDA) electrodes
  • Redox cycling

Fingerprint

Dive into the research topics of 'SU-8-based flexible amperometric device with IDA electrodes to regenerate redox species in small spaces'. Together they form a unique fingerprint.