The correlation between ultrasonographic findings and pathologic features in breast disorders

Kentaro Tamaki, Hironobu Sasano, Takanori Ishida, Kazuyuki Ishida, Minoru Miyashita, Motohiro Takeda, Masakazu Amari, Narumi Harada-Shoji, Masaaki Kawai, Toshiyuki Hayase, Nobumitsu Tamaki, Noriaki Ohuchi

Research output: Contribution to journalArticlepeer-review

26 Citations (Scopus)

Abstract

Objective: Breast ultrasonography has gained widespread acceptance as a diagnostic tool for the evaluation of human breast disorders. It is important to evaluate the correlation of ultrasonography findings with the corresponding histopathological features. Method: We retrospectively reviewed the 154 cases of breast disorders. We evaluated the correlation the ultrasonography findings and carcinoma cells extension with their corresponding histopathological findings. In addition, we also studied the information on estimation of histological types and cancer extension used by the other modalities such as computed tomography and magnetic resonance imaging. Results: The concordance rate for margins between ultrasonography findings and histopathological features was 91.6% (P < 0.001) and that for boundary zone was 87.0% (P < 0.001). Histopathological correlation of internal and posterior echoes demonstrated that internal low echo masses were composed of fibroblastic cells with marked collagenization in the stroma, or the cases in which carcinoma cells proliferated in a monotonous, solid and/or expanding manners. Attenuation of posterior echo was detected in the cases associated with hyperplasia of collagenized fibroblastic stroma. An increased cellularity in the mass with prominent large tumor nests and little fibrous stroma demonstrated the accentuation or no alterations of the posterior echo. The concordance rate of borders was 84.4% (P < 0.001). The correlation between estimated histological type by ultrasonography diagnosis and actual histological types was 87.0%. An overall detection rate of carcinoma extension by ultrasonography was 86.4%. In addition, an overall detection rate of carcinoma extension by ultrasonography, magnetic resonance imaging and computed tomography was 93.8%. Conclusion: These results demonstrated correlation between histopathological and ultrasonographic findings of the breast lesions is cardinal for quality control or improving the quality of ultrasonography.

Original languageEnglish
Article numberhyq070
Pages (from-to)905-912
Number of pages8
JournalJapanese Journal of Clinical Oncology
Volume40
Issue number10
DOIs
Publication statusPublished - 2010 May 21

Keywords

  • Breast ultrasound
  • Carcinoma extension
  • Histopathologic findings

Fingerprint

Dive into the research topics of 'The correlation between ultrasonographic findings and pathologic features in breast disorders'. Together they form a unique fingerprint.

Cite this