T1 - Transepidermal Potential of the Stretched Skin
AU - Abe, Yuina
AU - Konno, Hajime
AU - Yoshida, Shotaro
AU - Nishizawa, Matsuhiko
N1 - Publisher Copyright:
© 2019 by ASME.
PY - 2019/8/1
Y1 - 2019/8/1
N2 - The electrical response of the skin to mechanical stretches is reported here. The electrical potential difference across the epidermis, i.e., transepidermal potential (TEP) of porcine skin samples subjected to cyclic stretching, was measured in real time to observe electrochemical change in epidermal tissue. In addition to a conventional method of TEP measurement for the whole of skin sample, a probe-Type system with a fine-needle salt bridge was used for direct measurement of TEP at a targeted local point of the skin. TEP decreased with the increased mechanical stretches, and the change of TEP was found to be mostly occurred in the epidermis but not dermis nor hypodermis by comparing the results of conventional and the probe-Type methods. The observed change of TEP value was quick, reversible, and strain-dependent. Considering from such characteristic behaviors, one of the possible mechanisms of the modulation of TEP would be influence of the streaming potential caused by the fluid flow during the physical deformation of the epidermis.
AB - The electrical response of the skin to mechanical stretches is reported here. The electrical potential difference across the epidermis, i.e., transepidermal potential (TEP) of porcine skin samples subjected to cyclic stretching, was measured in real time to observe electrochemical change in epidermal tissue. In addition to a conventional method of TEP measurement for the whole of skin sample, a probe-Type system with a fine-needle salt bridge was used for direct measurement of TEP at a targeted local point of the skin. TEP decreased with the increased mechanical stretches, and the change of TEP was found to be mostly occurred in the epidermis but not dermis nor hypodermis by comparing the results of conventional and the probe-Type methods. The observed change of TEP value was quick, reversible, and strain-dependent. Considering from such characteristic behaviors, one of the possible mechanisms of the modulation of TEP would be influence of the streaming potential caused by the fluid flow during the physical deformation of the epidermis.
UR - http://www.scopus.com/inward/record.url?scp=85065523693&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85065523693&partnerID=8YFLogxK
U2 - 10.1115/1.4043522
DO - 10.1115/1.4043522
M3 - Article
C2 - 31004172
AN - SCOPUS:85065523693
SN - 0148-0731
VL - 141
JO - Journal of Biomechanical Engineering
JF - Journal of Biomechanical Engineering
IS - 8
M1 - 084503
ER -