Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study

Kunihiro Yoshioka, Ryoichi Tanaka, Hidenobu Takagi, Yuta Ueyama, Kei Kikuchi, Takuya Chiba, Kazumasa Arakita, Joanne D. Schuijf, Yasuo Saito

Research output: Contribution to journalArticlepeer-review

45 Citations (Scopus)

Abstract

Purpose: Preoperative identification of the artery of Adamkiewicz can help prevent postoperative spinal cord injury following thoracic and thoracoabdominal aortic repair. Several studies have demonstrated the feasibility of evaluating the artery of Adamkiewicz using multi-detector row computed tomography (CT), but precise visualization remains a challenge. The present study was conducted to evaluate the usefulness of ultra-high-resolution CT for visualizing the artery of Adamkiewicz with a slice thickness of 0.25 versus 0.5 mm in patients with aortic aneurysms. Methods: Our institutional review board approved this study. Twenty-four patients with thoracic and thoracoabdominal aneurysms were scanned with beam collimation of 0.25 mm × 128. Images were reconstructed with slice thicknesses of 0.25 and 0.5 mm. The signal-to-noise ratio (SNR) of the aorta and contrast-to-noise ratio (CNR) between the anterior spinal artery and spinal cord were measured. Two independent observers evaluated visualization of the artery of Adamkiewicz and its continuity between the anterior spinal artery and the aorta using a four-point scale. Results: No significant differences in the SNR of the aorta or CNR of the anterior spinal artery were observed between 0.25- and 0.5-mm slices. The average visualization score was significantly higher for 0.25-mm slices (3.58 ± 0.78) than for 0.5-mm slices (3.13 ± 0.99) (p = 0.01). The percentage of patients with nondiagnostic image quality was significantly lower for 0.25-mm slices (8.3%) than for 0.5-mm slices (33.3%) (p = 0.03). Conclusion: In patients with aortic aneurysms, ultra-high-resolution CT with 0.25-mm slices significantly improves visualization of the artery of Adamkiewicz compared to 0.5-mm slices.

Original languageEnglish
Pages (from-to)109-115
Number of pages7
JournalNeuroradiology
Volume60
Issue number1
DOIs
Publication statusPublished - 2018 Jan 1
Externally publishedYes

Keywords

  • Aortic aneurysm
  • Artery of Adamkiewicz
  • Computed tomography
  • Spinal cord
  • Ultra-high-resolution

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Clinical Neurology
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Ultra-high-resolution CT angiography of the artery of Adamkiewicz: a feasibility study'. Together they form a unique fingerprint.

Cite this