T1 - Use of intraoperative dynamic infrared imaging with detection wavelength of 7-14 μm in the surgical obliteration of spinal arteriovenous fistula
T2 - Case report and technical considerations
AU - Nakagawa, Atsuhiro
AU - Hirano, T.
AU - Uenohara, H.
AU - Utsunomiya, H.
AU - Suzuki, S.
AU - Takayama, K.
AU - Shirane, R.
AU - Tominaga, T.
PY - 2004/6
Y1 - 2004/6
N2 - Background and Objective: Although improvements of spatial and temporal resolution in infrared (IR) imaging have enabled intraoperative real-time acquisition of physiological and pathological information on living organs, the imaging qualities of anatomical delineation of blood vessels and functional delineation of blood flow were insufficient to serve as visual monitoring. The main reason was partly due to the lack of an appropriate IR detection IR band (formerly 3-5μm), and the broad dynamic range in previous modalities. Methods: To make a good contrast between blood vessels and surrounding tissues, the detection wavelength was shifted to the long-wave (7-14 μm) part of IR spectrum, which includes the peak IR wave from living tissue (9-10 μm), and the dynamic range was confined to ± 10 °C around 35 °C. The novel camera system (IRIS IV infrared imaging system) was used for the visual monitoring of blood flow during the obliteration of a spinal perimedullary arteriovenous fistula at Th 7 in 71-year-old male patient. The temperature resolution of camera was 0.15 °C, with its intensity resolution of 16 bit (320 x 240 pixels), and data were stored at a rate of 30 frames/second. High-quality delineation of blood vessels and blood flow was obtained all through the procedure without use of cold saline, which was an inevitable procedure to make contrast in the previously used thermography. However, the occasional use of an air blower was helpful to achieve adequate images in the deep and narrow area of the surgical field. The amount of shunt flow reduction was visualized by the intensity in the acquired imaging, which was also confirmed later by digital subtraction angiography. Conclusion: From the present experience, it is considered that this type of imaging may be able to substitute intraoperative blood vessel and blood flow monitoring in spinal and other neurosurgical disorders.
AB - Background and Objective: Although improvements of spatial and temporal resolution in infrared (IR) imaging have enabled intraoperative real-time acquisition of physiological and pathological information on living organs, the imaging qualities of anatomical delineation of blood vessels and functional delineation of blood flow were insufficient to serve as visual monitoring. The main reason was partly due to the lack of an appropriate IR detection IR band (formerly 3-5μm), and the broad dynamic range in previous modalities. Methods: To make a good contrast between blood vessels and surrounding tissues, the detection wavelength was shifted to the long-wave (7-14 μm) part of IR spectrum, which includes the peak IR wave from living tissue (9-10 μm), and the dynamic range was confined to ± 10 °C around 35 °C. The novel camera system (IRIS IV infrared imaging system) was used for the visual monitoring of blood flow during the obliteration of a spinal perimedullary arteriovenous fistula at Th 7 in 71-year-old male patient. The temperature resolution of camera was 0.15 °C, with its intensity resolution of 16 bit (320 x 240 pixels), and data were stored at a rate of 30 frames/second. High-quality delineation of blood vessels and blood flow was obtained all through the procedure without use of cold saline, which was an inevitable procedure to make contrast in the previously used thermography. However, the occasional use of an air blower was helpful to achieve adequate images in the deep and narrow area of the surgical field. The amount of shunt flow reduction was visualized by the intensity in the acquired imaging, which was also confirmed later by digital subtraction angiography. Conclusion: From the present experience, it is considered that this type of imaging may be able to substitute intraoperative blood vessel and blood flow monitoring in spinal and other neurosurgical disorders.
KW - Angiography
KW - Arteriovenous fistula
KW - Dynamic infrared imaging
KW - Intraoperative monitoring
KW - Spine
KW - Thermal artery imaging
UR - http://www.scopus.com/inward/record.url?scp=4544383157&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=4544383157&partnerID=8YFLogxK
U2 - 10.1055/s-2004-818493
DO - 10.1055/s-2004-818493
M3 - Article
C2 - 15343427
AN - SCOPUS:4544383157
SN - 0946-7211
VL - 47
SP - 136
EP - 139
JO - Minimally Invasive Neurosurgery
JF - Minimally Invasive Neurosurgery
IS - 3
ER -