TY - JOUR
T1 - Usefulness of the spectral shaping dual-source computed tomography imaging technique in posterior corrective fusion for adolescent idiopathic scoliosis
AU - Noto, Yoshiyuki
AU - Endo, Yuki
AU - Ohashi, Masayuki
AU - Hirano, Toru
AU - Kuramoto, Tatsuya
AU - Chida, Koichi
AU - Watanabe, Kei
N1 - Publisher Copyright:
© The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2024.
PY - 2024/2
Y1 - 2024/2
N2 - Purpose: Since childhood exposure to radiation has been demonstrated to increase cancer risk with increase in radiation dose, reduced radiation exposure during computed tomography (CT) evaluation is desired for adolescent idiopathic scoliosis (AIS). Therefore, this retrospective study aimed to investigate the radiation dose of dual-source CT using a spectral shaping technique and the accuracy of the thoracic pedicle screw (TPS) placement for posterior spinal fusion (PSF) in patients with AIS. Methods: Fifty-nine female patients with thoracic AIS who underwent PSF using CT-guided TPSs were included and divided into two groups comprised of 23 patients who underwent dual-source CT (DSCT) with a tin filter (DSCT group) and 36 who underwent conventional multislice CT (MSCT group). We assessed the CT radiation dose using the CT dose index (CTDIvol), effective dose (ED), and accuracy of TPS insertion according to the established Neo’s classification. Results: The DSCT and MSCT groups differed significantly (p < 0.001) in the mean CTDIvol (0.76 vs. 3.31 mGy, respectively) and ED (0.77 vs. 3.47 mSv, respectively). Although the correction rate of the main thoracic curve in the DSCT group was lower (65.7% vs. 71.2%) (p = 0.0126), the TPS accuracy (Grades 0–1) was similar in both groups (381 screws [88.8%] vs. 600 screws [88.4%], respectively) (p = 0.8133). No patient required replacement of malpositioned screws. Conclusion: Spectral shaping DSCT with a tube-based tin filter allowed a 75% radiation dose reduction while achieving TPS insertion accuracy similar to procedures based on conventional CT without spectral shaping.
AB - Purpose: Since childhood exposure to radiation has been demonstrated to increase cancer risk with increase in radiation dose, reduced radiation exposure during computed tomography (CT) evaluation is desired for adolescent idiopathic scoliosis (AIS). Therefore, this retrospective study aimed to investigate the radiation dose of dual-source CT using a spectral shaping technique and the accuracy of the thoracic pedicle screw (TPS) placement for posterior spinal fusion (PSF) in patients with AIS. Methods: Fifty-nine female patients with thoracic AIS who underwent PSF using CT-guided TPSs were included and divided into two groups comprised of 23 patients who underwent dual-source CT (DSCT) with a tin filter (DSCT group) and 36 who underwent conventional multislice CT (MSCT group). We assessed the CT radiation dose using the CT dose index (CTDIvol), effective dose (ED), and accuracy of TPS insertion according to the established Neo’s classification. Results: The DSCT and MSCT groups differed significantly (p < 0.001) in the mean CTDIvol (0.76 vs. 3.31 mGy, respectively) and ED (0.77 vs. 3.47 mSv, respectively). Although the correction rate of the main thoracic curve in the DSCT group was lower (65.7% vs. 71.2%) (p = 0.0126), the TPS accuracy (Grades 0–1) was similar in both groups (381 screws [88.8%] vs. 600 screws [88.4%], respectively) (p = 0.8133). No patient required replacement of malpositioned screws. Conclusion: Spectral shaping DSCT with a tube-based tin filter allowed a 75% radiation dose reduction while achieving TPS insertion accuracy similar to procedures based on conventional CT without spectral shaping.
KW - Adolescent idiopathic scoliosis
KW - Computed tomography
KW - Pedicle screw
KW - Posterior spinal fusion
KW - Spectral shaping technology
UR - http://www.scopus.com/inward/record.url?scp=85182415823&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85182415823&partnerID=8YFLogxK
U2 - 10.1007/s00586-023-08006-7
DO - 10.1007/s00586-023-08006-7
M3 - Article
C2 - 38233628
AN - SCOPUS:85182415823
SN - 0940-6719
VL - 33
SP - 706
EP - 712
JO - European Spine Journal
JF - European Spine Journal
IS - 2
ER -