TY - JOUR
T1 - Validity of the adaptive filter for accurate measurement of cardiac output in impedance cardiography
AU - Ono, Takashi
AU - Yasuda, Yoshifumi
AU - Ito, Tomonori
AU - Barros, Allan K.
AU - Ishida, Koji
AU - Miyamura, Miharu
AU - Yoshizawa, Makoto
AU - Yambe, Tomoyuki
PY - 2004/3
Y1 - 2004/3
N2 - The purpose of this study was to assess the validity of an adaptive filter, the scaled Fourier linear combiner (SFLC), in the impedance cardiography (ICG). Eight healthy males underwent constant-load bicycle exercise at different intensities from unloaded to near maximal intensity. The stroke volume (SV) and cardiac output (Q) measured by ICG at each condition were compared with those by the CO2 rebreathing method. We found that the noises were greatly reduced in the impedance waveform and that the inflection points, so-called the B- and X-points, were clearly detected even during strenuous exercise using the SFLC. Although a high correlation was observed between Qs measured by the two methods, the mean values of Qs in each method differed significantly and the regression line also differed significantly from the identity line. Likewise, a significant correlation was observed between SVs obtained by the two methods, but a significant difference in the group mean values and a trend of the regression line were observed. These findings suggest that the use of SFLC in ICG improves the performance in eliminating the noises and in detecting the inflection points in the waveform, thereby contributing to the accurate and beat-to-beat measurements of SV and Q especially during exercise.
AB - The purpose of this study was to assess the validity of an adaptive filter, the scaled Fourier linear combiner (SFLC), in the impedance cardiography (ICG). Eight healthy males underwent constant-load bicycle exercise at different intensities from unloaded to near maximal intensity. The stroke volume (SV) and cardiac output (Q) measured by ICG at each condition were compared with those by the CO2 rebreathing method. We found that the noises were greatly reduced in the impedance waveform and that the inflection points, so-called the B- and X-points, were clearly detected even during strenuous exercise using the SFLC. Although a high correlation was observed between Qs measured by the two methods, the mean values of Qs in each method differed significantly and the regression line also differed significantly from the identity line. Likewise, a significant correlation was observed between SVs obtained by the two methods, but a significant difference in the group mean values and a trend of the regression line were observed. These findings suggest that the use of SFLC in ICG improves the performance in eliminating the noises and in detecting the inflection points in the waveform, thereby contributing to the accurate and beat-to-beat measurements of SV and Q especially during exercise.
KW - Adaptive filter
KW - Cardiac output
KW - CO rebreathing
KW - Impedance cardiography
KW - Stroke volume
UR - http://www.scopus.com/inward/record.url?scp=1842845158&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=1842845158&partnerID=8YFLogxK
U2 - 10.1620/tjem.202.181
DO - 10.1620/tjem.202.181
M3 - Article
C2 - 15065644
AN - SCOPUS:1842845158
SN - 0040-8727
VL - 202
SP - 181
EP - 191
JO - Tohoku Journal of Experimental Medicine
JF - Tohoku Journal of Experimental Medicine
IS - 3
ER -