Working fluid sealing method for vapor chamber type micro thermal diode

Research output: Contribution to journalArticlepeer-review

Abstract

This paper reports a method to encapsulate degassed working fluid in a vapor chamber type micro thermal diode. Degassing and sealing processes were sequentially done in a same vacuum chamber. The pressure in the device, measured by a zero-balance method, was as low as 7000 Pa, and the pressure was kept for at least 500 hours. The thermal resistance in the reverse heat flow mode was about 30% higher than that in the forward mode.

Original languageEnglish
Pages (from-to)392-393
Number of pages2
JournalIEEJ Transactions on Sensors and Micromachines
Volume138
Issue number8
DOIs
Publication statusPublished - 2018

Keywords

  • Drop-wise condensation
  • Micro heat management
  • Power MEMS
  • Thermal diode
  • Vapor chamber

Fingerprint

Dive into the research topics of 'Working fluid sealing method for vapor chamber type micro thermal diode'. Together they form a unique fingerprint.