T1 - X-ray measurements from the cathode surface of glow discharge tube used as a compact X-ray fluorescence instrument
AU - Tsuji, Kouichi
AU - Wagatsuma, Kazuaki
AU - Yamaguchi, Sadae
AU - Nagata, Shinji
AU - Hirokawa, Kichinosuke
N1 - Funding Information:
Parts of this work were supported by a Grant-in-Aid for Encouragement of Young Scientists (No. 09750805) from the Ministry of Education, Science, Sports and Culture of Japan. The authors would like to thank Mr. S. Shucart for useful suggestions.
PY - 1998
Y1 - 1998
N2 - As previously reported, when a high-voltage is applied to a Grimm glow discharge tube, high-energy electrons emitted from the cathode surface bombard the glass window, leading to X-ray emissions from the window. In this study, we have applied an energy-dispersive X-ray analysis to detect X-rays from the cathode which are excited by X-rays emitted from the glass window. Thus, we have proposed to utilize this glow discharge tube as a compact X-ray fluorescence instrument, to which both the X-ray emission source and the sample are directly attached. This compact X-ray fluorescence instrument has the same advantages of easy maintenance, exchangeable target and sample, and simple construction. The quantitative determination of Si, Ti, and Mn in Fe-Si, Fe-Ti, and Fe-Mn alloys was demonstrated with the detection limits of 21, 150 and 420 ppm, respectively. The X-ray measurement form the cathode is a useful method to directly monitor the cathode surface during the glow discharge process. This would be applied to understand and control the glow discharge processes. Moreover, the X-ray diffraction peaks as well as the fluorescent X-ray peaks were observed, indicating that the structure analysis of the cathode material would also be possible.
AB - As previously reported, when a high-voltage is applied to a Grimm glow discharge tube, high-energy electrons emitted from the cathode surface bombard the glass window, leading to X-ray emissions from the window. In this study, we have applied an energy-dispersive X-ray analysis to detect X-rays from the cathode which are excited by X-rays emitted from the glass window. Thus, we have proposed to utilize this glow discharge tube as a compact X-ray fluorescence instrument, to which both the X-ray emission source and the sample are directly attached. This compact X-ray fluorescence instrument has the same advantages of easy maintenance, exchangeable target and sample, and simple construction. The quantitative determination of Si, Ti, and Mn in Fe-Si, Fe-Ti, and Fe-Mn alloys was demonstrated with the detection limits of 21, 150 and 420 ppm, respectively. The X-ray measurement form the cathode is a useful method to directly monitor the cathode surface during the glow discharge process. This would be applied to understand and control the glow discharge processes. Moreover, the X-ray diffraction peaks as well as the fluorescent X-ray peaks were observed, indicating that the structure analysis of the cathode material would also be possible.
UR - http://www.scopus.com/inward/record.url?scp=0032179349&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0032179349&partnerID=8YFLogxK
U2 - 10.1016/S0584-8547(98)00197-9
DO - 10.1016/S0584-8547(98)00197-9
M3 - Article
AN - SCOPUS:0032179349
SN - 0584-8547
VL - 53
SP - 1669
EP - 1677
JO - Spectrochimica Acta - Part B Atomic Spectroscopy
JF - Spectrochimica Acta - Part B Atomic Spectroscopy
IS - 12
ER -