移動中非接触給電システム用漏洩磁界低減コイル接続構成に関する検討

Masaki Yokosawa, Hisato Kojima, Fumihiro Sato, Satoshi Miyahara, Hidetoshi Matsuki, Ken Inada, Shu Sasaki

研究成果: ジャーナルへの寄稿学術論文査読

抄録

In recent years, factory automation and automated guided vehicles (AGVs), which play a role in factory automation, have been attracting attention from the perspectives of securing labor, reducing labor costs, and increasing work efficiency. AGVs are mainly used for transporting and towing cargo, and can perform complex tasks by mounting a robot arm on the AGV. AGVs operate on storage batteries, which must be recharged or replaced, or the AGV itself must be replaced. In addition, work is interrupted when replacing storage batteries, which reduces work efficiency and indirectly affects costs such as labor costs. Therefore, the use of contactless power supply during transportation and during work can improve efficiency without worrying about the remaining storage battery level. In this paper, we discuss the configuration of a system for contactless power supply to mobility vehicles while they are moving.

寄稿の翻訳タイトルStudy on the Configuration of Leakage Magnetic Field Reduction Coil Connection for Contactless Power Transfer System in Moving
本文言語Japanese
ページ(範囲)251-257
ページ数7
ジャーナルIEEJ Transactions on Fundamentals and Materials
143
7
DOI
出版ステータス出版済み - 2023

キーワード

  • 8-shaped coil
  • AGV
  • magnetic field leakage reduction
  • mobility
  • power supply while moving
  • wireless power transfer