TY - JOUR
T1 - A Micro-flow Phantom for Superficial Micro-vasculature Imaging
AU - Bhatti, A.
AU - Ishii, T.
AU - Saijo, Y.
N1 - Publisher Copyright:
© 2021 Institute of Physics Publishing. All rights reserved.
PY - 2021/11/25
Y1 - 2021/11/25
N2 - Visualization of cutaneous micro-vasculatures is a powerful approach assisting in the diagnosis of skin vascular disorders. These minute structures can be visualized by high-frequency ultrasound (HFUS) using ultrafast Doppler imaging. Ultrasound flow phantoms have been used as assessment tools to evaluate the performance of the ultrasound imaging system, however, to optimize the imaging system for visualization of micro-structures, flow phantom with micro-channels is required which are usually difficult to fabricate. Here, we design a simple approach for micro-flow phantom which is easy to fabricate and cast for detection of microcirculation in superficial micro-structures. The proposed approach features (i) the micro-channels of 200-micron at the depth of 4 mm (ii) casted in the cryogel mixture of Poly-vinyl alcohol (PVA) and (iii) infused at flow speed of 30 mm/s using infusion pump. Visualization of micro-flow channel in power Doppler image obtained by HFUS ultrafast Doppler imaging reveals that the proposed micro-flow phantom could serve as a viable assessment tool for optimizing the system for in-vivo cutaneous micro-vasculature imaging.
AB - Visualization of cutaneous micro-vasculatures is a powerful approach assisting in the diagnosis of skin vascular disorders. These minute structures can be visualized by high-frequency ultrasound (HFUS) using ultrafast Doppler imaging. Ultrasound flow phantoms have been used as assessment tools to evaluate the performance of the ultrasound imaging system, however, to optimize the imaging system for visualization of micro-structures, flow phantom with micro-channels is required which are usually difficult to fabricate. Here, we design a simple approach for micro-flow phantom which is easy to fabricate and cast for detection of microcirculation in superficial micro-structures. The proposed approach features (i) the micro-channels of 200-micron at the depth of 4 mm (ii) casted in the cryogel mixture of Poly-vinyl alcohol (PVA) and (iii) infused at flow speed of 30 mm/s using infusion pump. Visualization of micro-flow channel in power Doppler image obtained by HFUS ultrafast Doppler imaging reveals that the proposed micro-flow phantom could serve as a viable assessment tool for optimizing the system for in-vivo cutaneous micro-vasculature imaging.
UR - http://www.scopus.com/inward/record.url?scp=85122037997&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85122037997&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/2071/1/012054
DO - 10.1088/1742-6596/2071/1/012054
M3 - Conference article
AN - SCOPUS:85122037997
SN - 1742-6588
VL - 2071
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
IS - 1
M1 - 012054
T2 - 2021 International Conference on Biomedical Engineering, ICoBE 2021
Y2 - 14 September 2021 through 15 September 2021
ER -