TY - JOUR
T1 - A New Quantitative Triage System for Hospitalized Neonates to Assist with Decisions of Hospital Evacuation Priorities
AU - Imai, Kazunori
AU - Suzuki, Tomoko
AU - Fukaya, Satoko
AU - Karasawa, Yuko
AU - Bando, Yoko
AU - Sawaki, Daisuke
AU - Araki, Yuko
AU - Saitoh, Shinji
AU - Iwata, Osuke
N1 - Funding Information:
The authors thank Ms. Takako Nishio, Ms. Miyu Koike, and Ms. Ayaka Kashima for their considerable help with data collection, and the staff of the NICU for their continuous support during the study.
Publisher Copyright:
© The Author(s), 2022. Published by Cambridge University Press on behalf of the World Association for Disaster and Emergency Medicine
PY - 2022/6/7
Y1 - 2022/6/7
N2 - Abstract Introduction: Hospitalized neonates are vulnerable to natural and man-made disasters because of their persistent requirement for medical resources and may need to be evacuated to safe locations when electricity and medical gas supply become unreliable. In Japan, a triage system for hospitalized neonates, or the Simple Triage and Rapid Treatment for Neonates, Revised (START-Neo-R), has been used to determine whether neonates are in suitable conditions for transportation. However, this scale is not useful to determine the evacuation order of neonates because a considerable number of evacuees are classified into the same categories. Study Objective: To solve this problem, a novel triage system, Neonatal Extrication Triage (NEXT) was developed. This study tested the validity and reproducibility of both triages and compared them with a standardized prognostic scoring system for hospitalized neonates, the Neonatal Therapeutic Intervention Scoring System (NTISS). Methods: In this retrospective observational study, physicians and nurses independently assessed each neonate hospitalized at a tertiary neonatal intensive care unit (NICU) twice weekly using NEXT and START-Neo-R. The NEXT system comprises six questionnaires regarding medical resources required during transition and transportation, providing composite scores on a 12-point scale. The START-Neo-R classified neonates into five levels based on the severity of disease and dependence on medical care. Inter-rater reliability of both systems was assessed using Cohen’s kappa coefficient, whereas the criterion validity with NTISS was assessed using Spearman’s correlation coefficient. Results: Overall, 162 neonates were assessed for 49 days, resulting in triage data for 1,079 accumulated patients. Both NEXT scores and START-Neo-R ranks were well-dispersed across different levels without excessive accumulation in specific categories. Inter-rater reliability of NEXT (kappa coefficient, 0.973; 95% confidence interval, 0.969-0.976) and START-Neo-R (kappa coefficient, 0.952; 95% confidence interval, 0.946-0.957) between physicians and nurses was sufficiently high. The correlation coefficient of NEXT and START-Neo-R scores with NTISS scores were 0.889 (P <.001) and 0.850 (P <.001), respectively. Conclusions: Both START-Neo-R and NEXT had good reproducibility and correlation with the severity of neonates indicated by NTISS. With its well-dispersed scores across different levels, the NEXT system might be a powerful tool to determine the priority of evacuation objectively.
AB - Abstract Introduction: Hospitalized neonates are vulnerable to natural and man-made disasters because of their persistent requirement for medical resources and may need to be evacuated to safe locations when electricity and medical gas supply become unreliable. In Japan, a triage system for hospitalized neonates, or the Simple Triage and Rapid Treatment for Neonates, Revised (START-Neo-R), has been used to determine whether neonates are in suitable conditions for transportation. However, this scale is not useful to determine the evacuation order of neonates because a considerable number of evacuees are classified into the same categories. Study Objective: To solve this problem, a novel triage system, Neonatal Extrication Triage (NEXT) was developed. This study tested the validity and reproducibility of both triages and compared them with a standardized prognostic scoring system for hospitalized neonates, the Neonatal Therapeutic Intervention Scoring System (NTISS). Methods: In this retrospective observational study, physicians and nurses independently assessed each neonate hospitalized at a tertiary neonatal intensive care unit (NICU) twice weekly using NEXT and START-Neo-R. The NEXT system comprises six questionnaires regarding medical resources required during transition and transportation, providing composite scores on a 12-point scale. The START-Neo-R classified neonates into five levels based on the severity of disease and dependence on medical care. Inter-rater reliability of both systems was assessed using Cohen’s kappa coefficient, whereas the criterion validity with NTISS was assessed using Spearman’s correlation coefficient. Results: Overall, 162 neonates were assessed for 49 days, resulting in triage data for 1,079 accumulated patients. Both NEXT scores and START-Neo-R ranks were well-dispersed across different levels without excessive accumulation in specific categories. Inter-rater reliability of NEXT (kappa coefficient, 0.973; 95% confidence interval, 0.969-0.976) and START-Neo-R (kappa coefficient, 0.952; 95% confidence interval, 0.946-0.957) between physicians and nurses was sufficiently high. The correlation coefficient of NEXT and START-Neo-R scores with NTISS scores were 0.889 (P <.001) and 0.850 (P <.001), respectively. Conclusions: Both START-Neo-R and NEXT had good reproducibility and correlation with the severity of neonates indicated by NTISS. With its well-dispersed scores across different levels, the NEXT system might be a powerful tool to determine the priority of evacuation objectively.
KW - disaster
KW - evacuation
KW - neonatal intensive care unit
KW - neonate
KW - triage
UR - http://www.scopus.com/inward/record.url?scp=85128400388&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85128400388&partnerID=8YFLogxK
U2 - 10.1017/S1049023X22000553
DO - 10.1017/S1049023X22000553
M3 - Article
C2 - 35388784
AN - SCOPUS:85128400388
SN - 1049-023X
VL - 37
SP - 343
EP - 349
JO - Prehospital and Disaster Medicine
JF - Prehospital and Disaster Medicine
IS - 3
ER -