TY - JOUR
T1 - Compton spectroscopy for rotation-mode computed tomography
AU - Mohammadi, A.
AU - Baba, M.
AU - Nakhostin, M.
AU - Ohuchi, H.
AU - Abe, M.
PY - 2012
Y1 - 2012
N2 - In computed tomography (CT) systems, it is desirable to know the X-ray energy spectra for various applications, including medical CT imaging, and diagnostic field and heavy ion therapy. However, because of the restricted space, the only practical solution is to use Compton spectroscopy, where the incident spectrum is inferred from the scattered spectrum. The geometry of the scatterer and its position within the CT can affect the spectrum of the secondary beam, making it difficult to determine the primary spectrum during operation of the CT system. A modified Compton spectrometer is described that allows measurement of the X-ray energy spectra during operation, and most importantly, in rotation mode. The geometry of the scatterer was optimized to reduce the energy broadening of the secondary beam. The performance of the system was evaluated by comparing the reconstructed exposure to that measured directly using an ion chamber.
AB - In computed tomography (CT) systems, it is desirable to know the X-ray energy spectra for various applications, including medical CT imaging, and diagnostic field and heavy ion therapy. However, because of the restricted space, the only practical solution is to use Compton spectroscopy, where the incident spectrum is inferred from the scattered spectrum. The geometry of the scatterer and its position within the CT can affect the spectrum of the secondary beam, making it difficult to determine the primary spectrum during operation of the CT system. A modified Compton spectrometer is described that allows measurement of the X-ray energy spectra during operation, and most importantly, in rotation mode. The geometry of the scatterer was optimized to reduce the energy broadening of the secondary beam. The performance of the system was evaluated by comparing the reconstructed exposure to that measured directly using an ion chamber.
KW - Compton spectroscopy
KW - X-ray spectrum
KW - computed tomography
KW - rotation mode
UR - http://www.scopus.com/inward/record.url?scp=84866140223&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84866140223&partnerID=8YFLogxK
U2 - 10.3233/XST-2012-0324
DO - 10.3233/XST-2012-0324
M3 - Article
C2 - 22635170
AN - SCOPUS:84866140223
SN - 0895-3996
VL - 20
SP - 131
EP - 140
JO - Journal of X-Ray Science and Technology
JF - Journal of X-Ray Science and Technology
IS - 2
ER -