TY - JOUR
T1 - Control of treatment size in cavitation-enhanced high-intensity focused ultrasound using radio-frequency echo signals
AU - Tomiyasu, Kentaro
AU - Takagi, Ryo
AU - Iwasaki, Ryosuke
AU - Yoshizawa, Shin
AU - Umemura, Shin Ichiro
N1 - Publisher Copyright:
© 2017 The Japan Society of Applied Physics.
PY - 2017/7
Y1 - 2017/7
N2 - In high-intensity focused ultrasound (HIFU) treatment, controlling the ultrasound dose at each focal target spot is important because it is a problem that the length of the coagulated region in front of the focal point deviates owing to the differences in absorption in each focal target spot and attenuation in the intervening tissues. In this study, the detected changes in the power spectra of HIFU echoes were used by controlling the HIFU duration in the "trigger HIFU" sequence with the aim to increase coagulation size through the enhancement of the ultrasonic heating by the cavitation induced by the preceding extremely high intensity short "trigger" pulse. The result shows that this method can be used to detect boiling bubbles and the following generated cavitation bubbles at their early stage. By automatically stopping HIFU exposure immediately after detecting the bubbles, overheating was prevented and the deviation of the length of the coagulated region was reduced.
AB - In high-intensity focused ultrasound (HIFU) treatment, controlling the ultrasound dose at each focal target spot is important because it is a problem that the length of the coagulated region in front of the focal point deviates owing to the differences in absorption in each focal target spot and attenuation in the intervening tissues. In this study, the detected changes in the power spectra of HIFU echoes were used by controlling the HIFU duration in the "trigger HIFU" sequence with the aim to increase coagulation size through the enhancement of the ultrasonic heating by the cavitation induced by the preceding extremely high intensity short "trigger" pulse. The result shows that this method can be used to detect boiling bubbles and the following generated cavitation bubbles at their early stage. By automatically stopping HIFU exposure immediately after detecting the bubbles, overheating was prevented and the deviation of the length of the coagulated region was reduced.
UR - http://www.scopus.com/inward/record.url?scp=85025102579&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85025102579&partnerID=8YFLogxK
U2 - 10.7567/JJAP.56.07JF28
DO - 10.7567/JJAP.56.07JF28
M3 - Article
AN - SCOPUS:85025102579
SN - 0021-4922
VL - 56
JO - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes
JF - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes
IS - 7
M1 - 07JF28
ER -