TY - JOUR
T1 - Cookson-type reagents
T2 - Highly sensitive derivatization reagents for conjugated dienes in high-performance liquid chromatography
AU - Shimada, Kazutake
AU - Oe, Tomoyuki
AU - Mizuguchi, Tatsuhito
PY - 1991
Y1 - 1991
N2 - Cookson-type reagents, 4-substituted 1,2,4-triazoline-3,5-diones, having a chromophore, fluorophore or electrophore at the 4-position, have been synthesized for high-performance liquid chromatographic measurements of conjugated dienes. The reactivity of these reagents and the properties of their adducts were examined by using 7-dehydrocholesterol (7-DHC) as a model compound. 4-(1-Anthryl)- and 4-(1-pyrenyl)-1,2,4-triazoline-3,5-dione quantitatively produced adducts, in 5 min under ice-cooling, that could be detected using an ultraviolet detector but not a fluorescence detector. The adducts with 4-[2-(1-pyrenyl)ethyl]- and 4-amino-1,2,4-triazoline-3,5-dione were also easily formed and could be easily detected using fluorescence [detection limit: signal-to-noise ratio (S/N) = 5, 0.025 pmol] and electrochemical (S/N = 5, 0.029 pmol) detectors, respectively. The chromatographic behaviour of the adducts with 7-DHC and vitamin D3, and the application of the method to the detection of 7-DHC in human skin, are also reported.
AB - Cookson-type reagents, 4-substituted 1,2,4-triazoline-3,5-diones, having a chromophore, fluorophore or electrophore at the 4-position, have been synthesized for high-performance liquid chromatographic measurements of conjugated dienes. The reactivity of these reagents and the properties of their adducts were examined by using 7-dehydrocholesterol (7-DHC) as a model compound. 4-(1-Anthryl)- and 4-(1-pyrenyl)-1,2,4-triazoline-3,5-dione quantitatively produced adducts, in 5 min under ice-cooling, that could be detected using an ultraviolet detector but not a fluorescence detector. The adducts with 4-[2-(1-pyrenyl)ethyl]- and 4-amino-1,2,4-triazoline-3,5-dione were also easily formed and could be easily detected using fluorescence [detection limit: signal-to-noise ratio (S/N) = 5, 0.025 pmol] and electrochemical (S/N = 5, 0.029 pmol) detectors, respectively. The chromatographic behaviour of the adducts with 7-DHC and vitamin D3, and the application of the method to the detection of 7-DHC in human skin, are also reported.
UR - http://www.scopus.com/inward/record.url?scp=0026353847&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0026353847&partnerID=8YFLogxK
U2 - 10.1039/AN9911601393
DO - 10.1039/AN9911601393
M3 - Article
AN - SCOPUS:0026353847
SN - 0003-2654
VL - 116
SP - 1393
EP - 1397
JO - The Analyst
JF - The Analyst
IS - 12
ER -