Cooling water system design of Japan's DEMO for fusion power production

The Joint Special Design Team for Fusion DEMO

研究成果: ジャーナルへの寄稿学術論文査読

25 被引用数 (Scopus)

抄録

Considering the water cooling system in fusion reactors, there are several fusion-specific challenges in designs of in-vessel components and their cooling water systems (CWS). In this research, solutions of the challenges have been discussed and indicate the CWS concept of Japan's DEMO. The CWS transfers thermal energy of blanket and a part of divertor to a generator system, and thermal energy of the other part of divertor is used as heat utilization in plant. The required performance of system devices such as pumps is expected to be achieved by proven technologies and its extensions. It is also indicated that blanket can work as the low-pass filter, and can suppress the effect of fusion output fluctuation. The designed cooling water system requires 70 MW electric power and generates 620 MW power with a 1.5 GW fusion power plasma. This research indicates the basic concept of Japan's DEMO CWS that can be practically achieved.

本文言語英語
ページ(範囲)110-115
ページ数6
ジャーナルFusion Engineering and Design
126
DOI
出版ステータス出版済み - 2018 1月

フィンガープリント

「Cooling water system design of Japan's DEMO for fusion power production」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル