Crack Detection of CFRP Cable Using ECT with Saw-Wave Excitation

Dongfeng He, Mitsuharu Shiwa, Kimiyoshi Naito

研究成果: Chapter

抄録

We developed eddy current testing (ECT) devices with saw-wave excitation. The saw wave has many harmonics, which can be used to get more information about defects. Multi-frequency digital lock-in amplifier for the harmonics was developed based on labview program. Using the saw-wave ECT, we did the experiments of crack detection for CFRP cable. An excitation coil and differential receiver coil were wrapped around a tube. The CFRP cable was moved through the tube for crack detection. The diameter of the CFRP cable was 1.3 mm and the diameter was 2.5 mm with the plastic coating. Three artificial defects with the interval of 50 mm were made. The depths of the cracks were about 1/4, 2/4, and 3/4 of the diameter of the cable respectively. Using the saw-wave ECT with the fundamental frequency of 200 kHz and the excitation current of 20 mA, the artificial defects in the CFRP cable was successfully detected.

本文言語English
ホスト出版物のタイトルElectromagnetic Nondestructive Evaluation (XIX)
編集者Tetsuya Uchimoto, Hiroaki Kikuchi, Noritaka Yusa
出版社IOS Press
ページ34-39
ページ数6
ISBN(電子版)9781614996385
DOI
出版ステータスPublished - 2016
外部発表はい

出版物シリーズ

名前Studies in Applied Electromagnetics and Mechanics
41
ISSN(印刷版)1383-7281
ISSN(電子版)1879-8322

ASJC Scopus subject areas

  • 機械工学
  • 電子工学および電気工学

フィンガープリント

「Crack Detection of CFRP Cable Using ECT with Saw-Wave Excitation」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル