T1 - Development of a cylindrical tracking detector with multichannel scintillation fibers and pixelated photon detector readout
AU - Akazawa, Y.
AU - Miwa, K.
AU - Honda, Ryotaro
AU - Shiozaki, T.
AU - Chiga, N.
N1 - Publisher Copyright:
© 2014 Elsevier B.V. All rights reserved.
PY - 2015/7/1
Y1 - 2015/7/1
N2 - Abstract We are developing a cylindrical tracking detector for a Σp scattering experiment in J-PARC with scintillation fibers and the Pixelated Photon Detector (PPD) readout, which is called as cylindrical fiber tracker (CFT), in order to reconstruct trajectories of charged particles emitted inside CFT. CFT works not only as a tracking detector but also a particle identification detector from energy deposits. A prototype CFT consisting of two straight layers and one spiral layer was constructed. About 1100 scintillation fibers with a diameter of 0.75 mm (Kuraray SCSF-78 M) were used. Each fiber signal was read by Multi-Pixel Photon Counter (MPPC, HPK S10362-11-050P, 1×1 mm2, 400 pixels) fiber by fiber. MPPCs were handled with Extended Analogue Silicon Photomultipliers Integrated ReadOut Chip (EASIROC) boards, which were developed for the readout of a large number of MPPCs. The energy resolution of one layer was 28% for a 70 MeV proton where the energy deposit in fibers was 0.7 MeV.
AB - Abstract We are developing a cylindrical tracking detector for a Σp scattering experiment in J-PARC with scintillation fibers and the Pixelated Photon Detector (PPD) readout, which is called as cylindrical fiber tracker (CFT), in order to reconstruct trajectories of charged particles emitted inside CFT. CFT works not only as a tracking detector but also a particle identification detector from energy deposits. A prototype CFT consisting of two straight layers and one spiral layer was constructed. About 1100 scintillation fibers with a diameter of 0.75 mm (Kuraray SCSF-78 M) were used. Each fiber signal was read by Multi-Pixel Photon Counter (MPPC, HPK S10362-11-050P, 1×1 mm2, 400 pixels) fiber by fiber. MPPCs were handled with Extended Analogue Silicon Photomultipliers Integrated ReadOut Chip (EASIROC) boards, which were developed for the readout of a large number of MPPCs. The energy resolution of one layer was 28% for a 70 MeV proton where the energy deposit in fibers was 0.7 MeV.
KW - Energy resolution
KW - MPPC
KW - Scintillation fiber
KW - Tracking detector
UR - http://www.scopus.com/inward/record.url?scp=84939950143&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84939950143&partnerID=8YFLogxK
U2 - 10.1016/j.nima.2014.11.102
DO - 10.1016/j.nima.2014.11.102
M3 - Article
AN - SCOPUS:84939950143
SN - 0168-9002
VL - 787
SP - 193
EP - 196
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
M1 - 57261
ER -