TY - JOUR
T1 - Differentiating optic neuropathies using laser speckle flowgraphy
T2 - Evaluating blood flow patterns in the optic nerve head and peripapillary choroid
AU - Yamaguchi, Chiaki
AU - Kiyota, Naoki
AU - Himori, Noriko
AU - Omodaka, Kazuko
AU - Tsuda, Satoru
AU - Nakazawa, Toru
N1 - Publisher Copyright:
© 2024 The Author(s). Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.
PY - 2025/2
Y1 - 2025/2
N2 - Purpose: To compare blood flow (BF) impairment patterns in different optic neuropathies using laser speckle flowgraphy (LSFG). Methods: This retrospective study enrolled 24 eyes of 24 patients with non-arteritic anterior ischemic optic neuropathy (NAAION), 59 eyes of 59 patients with optic neuritis (ON), 677 eyes of 677 patients with open-angle glaucoma (OAG), and 110 eyes of 110 controls. The patient backgrounds of all groups were compared. Ophthalmologic findings were evaluated, adjusting for age, sex, blood pressure, pulse rate, and underlying systemic diseases with 1:1 optimal propensity score matching. We used LSFG to obtain optic nerve head (ONH) vessel-area mean blur rate (MBR; ONH-MV), ONH tissue-area MBR (ONH-MT), and choroidal MBR. The NAAION and ON groups were compared with the control and OAG groups. Results: Best-corrected visual acuity was worse in the NAAION, ON, and OAG groups than in controls (p < 0.001). Circumpapillary retinal nerve fibre layer thickness was higher in the NAAION and ON groups and lower in the OAG group than in controls (p < 0.001). Compared to controls, the NAAION and OAG groups had significantly lower ONH-MV, ONH-MT, and choroidal MBR (p < 0.05). Additionally, the NAAION group had lower ONH-MV and choroidal MBR than the OAG group (p = 0.003 and p < 0.001, respectively) but no difference in ONH-MT (p = 0.857). The ON group had significantly lower ONH-MV and choroidal MBR compared to the controls (p < 0.001 and p = 0.022, respectively) but no difference in ONH-MT (p = 0.773). Conclusion: Optic neuropathies showed different patterns of ocular BF impairment. Therefore, LSFG can be a useful tool for differentiating optic neuropathies.
AB - Purpose: To compare blood flow (BF) impairment patterns in different optic neuropathies using laser speckle flowgraphy (LSFG). Methods: This retrospective study enrolled 24 eyes of 24 patients with non-arteritic anterior ischemic optic neuropathy (NAAION), 59 eyes of 59 patients with optic neuritis (ON), 677 eyes of 677 patients with open-angle glaucoma (OAG), and 110 eyes of 110 controls. The patient backgrounds of all groups were compared. Ophthalmologic findings were evaluated, adjusting for age, sex, blood pressure, pulse rate, and underlying systemic diseases with 1:1 optimal propensity score matching. We used LSFG to obtain optic nerve head (ONH) vessel-area mean blur rate (MBR; ONH-MV), ONH tissue-area MBR (ONH-MT), and choroidal MBR. The NAAION and ON groups were compared with the control and OAG groups. Results: Best-corrected visual acuity was worse in the NAAION, ON, and OAG groups than in controls (p < 0.001). Circumpapillary retinal nerve fibre layer thickness was higher in the NAAION and ON groups and lower in the OAG group than in controls (p < 0.001). Compared to controls, the NAAION and OAG groups had significantly lower ONH-MV, ONH-MT, and choroidal MBR (p < 0.05). Additionally, the NAAION group had lower ONH-MV and choroidal MBR than the OAG group (p = 0.003 and p < 0.001, respectively) but no difference in ONH-MT (p = 0.857). The ON group had significantly lower ONH-MV and choroidal MBR compared to the controls (p < 0.001 and p = 0.022, respectively) but no difference in ONH-MT (p = 0.773). Conclusion: Optic neuropathies showed different patterns of ocular BF impairment. Therefore, LSFG can be a useful tool for differentiating optic neuropathies.
KW - glaucoma
KW - ischemic optic neuropathy
KW - laser speckle flowgraphy
KW - optic neuritis
UR - http://www.scopus.com/inward/record.url?scp=85201061053&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85201061053&partnerID=8YFLogxK
U2 - 10.1111/aos.16747
DO - 10.1111/aos.16747
M3 - Article
AN - SCOPUS:85201061053
SN - 1755-375X
VL - 103
SP - e49-e57
JO - Acta Ophthalmologica
JF - Acta Ophthalmologica
IS - 1
ER -