TY - JOUR
T1 - Effectiveness of Indirect and Direct Laryngoscopes in Pediatric Patients
T2 - A Systematic Review and Network Meta-Analysis
AU - Hoshijima, Hiroshi
AU - Mihara, Takahiro
AU - Kokubu, Shinichi
AU - Takeda, Sakura
AU - Shiga, Toshiya
AU - Mizuta, Kentaro
N1 - Publisher Copyright:
© 2022 by the authors.
PY - 2022/9
Y1 - 2022/9
N2 - This research aimed to produce a coherent ranking of the effectiveness of intubation devices in pediatric patients using network meta-analysis (NMA). We searched the electric databases for prospective randomized studies that compared different tracheal intubation devices in pediatric patients. The primary outcome was intubation failure at the first attempt. Secondary outcomes were glottic visualization and intubation time. The statistical analysis performed used DerSimonian and Laird random-effects models. Frequentist network meta-analysis was conducted, and network plots and network league tables were produced. Subgroup analysis was performed after excluding rigid-fiberscope-type indirect laryngoscopes. Thirty-four trials comparing 13 devices were included. Most laryngoscopes had the same intubation failure rate as the Macintosh reference device. Only the Truview PCD™ had a significantly higher intubation failure rate than the Macintosh (odds ratio 4.78, 95% confidence interval 1.11–20.6) The highest-ranking laryngoscope was the Airtaq™ (P score, 0.90), and the AirwayScope™, McGrath™, and Truview EVO2™ ranked higher than the Macintosh. The Bullard™ had the lowest ranking (P score, 0.08). All laryngoscopes had the same level of glottic visualization as the Macintosh and only the C-MAC™ had a significantly shorter intubation time. Intubation time was significantly longer when using the GlideScope™, Storz DCI™, Truview PCD™, or Bullard™ compared with the Macintosh. P score and ranking of devices in the subgroup analyses were similar to those in the main analysis. We applied NMA to create a consistent ranking of the effectiveness of intubation devices in pediatric patients. The findings of NMA suggest that there is presently no laryngoscope superior to the Macintosh laryngoscope in terms of tracheal intubation failure rate and glottic visualization in pediatric patients.
AB - This research aimed to produce a coherent ranking of the effectiveness of intubation devices in pediatric patients using network meta-analysis (NMA). We searched the electric databases for prospective randomized studies that compared different tracheal intubation devices in pediatric patients. The primary outcome was intubation failure at the first attempt. Secondary outcomes were glottic visualization and intubation time. The statistical analysis performed used DerSimonian and Laird random-effects models. Frequentist network meta-analysis was conducted, and network plots and network league tables were produced. Subgroup analysis was performed after excluding rigid-fiberscope-type indirect laryngoscopes. Thirty-four trials comparing 13 devices were included. Most laryngoscopes had the same intubation failure rate as the Macintosh reference device. Only the Truview PCD™ had a significantly higher intubation failure rate than the Macintosh (odds ratio 4.78, 95% confidence interval 1.11–20.6) The highest-ranking laryngoscope was the Airtaq™ (P score, 0.90), and the AirwayScope™, McGrath™, and Truview EVO2™ ranked higher than the Macintosh. The Bullard™ had the lowest ranking (P score, 0.08). All laryngoscopes had the same level of glottic visualization as the Macintosh and only the C-MAC™ had a significantly shorter intubation time. Intubation time was significantly longer when using the GlideScope™, Storz DCI™, Truview PCD™, or Bullard™ compared with the Macintosh. P score and ranking of devices in the subgroup analyses were similar to those in the main analysis. We applied NMA to create a consistent ranking of the effectiveness of intubation devices in pediatric patients. The findings of NMA suggest that there is presently no laryngoscope superior to the Macintosh laryngoscope in terms of tracheal intubation failure rate and glottic visualization in pediatric patients.
KW - direct laryngoscopes
KW - indirect laryngoscopes
KW - network meta-analysis
KW - pediatric
UR - http://www.scopus.com/inward/record.url?scp=85138666967&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85138666967&partnerID=8YFLogxK
U2 - 10.3390/children9091280
DO - 10.3390/children9091280
M3 - Article
AN - SCOPUS:85138666967
SN - 2227-9067
VL - 9
JO - Children
JF - Children
IS - 9
M1 - 1280
ER -