T1 - Evaluation and development for positron emission mammography based on Pr:LuAG scintillator crystals
AU - Sato, Hiroki
AU - Ito, Shigeki
AU - Usuki, Yoshiyuki
AU - Miyake, Masayasu
AU - Kumagai, Kazuaki
AU - Baba, Mamoru
AU - Ito, Masatoshi
AU - Yamamoto, Seiichi
PY - 2012/12/1
Y1 - 2012/12/1
N2 - In this report, PEM scanner using a Pr:LuAG scintillator crystal will be discussed. We have developed the PEM scanner with planer detectors which can change the angle and the distance depending on the condition of diagnosis. The planer detectors were composed of four units respectively and one unit consisted of a 20 × 64 pixels scintillator array optically coupled with three H8500 multi anode photomultipliers. As a scintillator Pr:LuAG was installed which possesses interesting properties such as a very fast decay time of 20 ns and a good energy resolution of 4.2 %. The Pr:LuAG pixel size was 2.1 mm × 2.1 mm × 15 mm and the BaSO4-type reflector was used for the array assembly. Based on this PEM system we have performed the clinical studies and compared with the images detected by the PET scanner. Because the spatial resolution of PEM is better than PET, advantages of PEM scanner were clearly shown.
AB - In this report, PEM scanner using a Pr:LuAG scintillator crystal will be discussed. We have developed the PEM scanner with planer detectors which can change the angle and the distance depending on the condition of diagnosis. The planer detectors were composed of four units respectively and one unit consisted of a 20 × 64 pixels scintillator array optically coupled with three H8500 multi anode photomultipliers. As a scintillator Pr:LuAG was installed which possesses interesting properties such as a very fast decay time of 20 ns and a good energy resolution of 4.2 %. The Pr:LuAG pixel size was 2.1 mm × 2.1 mm × 15 mm and the BaSO4-type reflector was used for the array assembly. Based on this PEM system we have performed the clinical studies and compared with the images detected by the PET scanner. Because the spatial resolution of PEM is better than PET, advantages of PEM scanner were clearly shown.
UR - http://www.scopus.com/inward/record.url?scp=84881581695&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84881581695&partnerID=8YFLogxK
U2 - 10.1109/NSSMIC.2012.6551809
DO - 10.1109/NSSMIC.2012.6551809
M3 - Conference contribution
AN - SCOPUS:84881581695
SN - 9781467320306
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 3537
EP - 3539
BT - 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, NSS/MIC 2012
T2 - 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, NSS/MIC 2012
Y2 - 29 October 2012 through 3 November 2012
ER -