抄録
A digital signal processing (DSP) system is applied to stilbene scintillation detectors of the multichannel neutron emission profile monitor in JT-60U. Automatic analysis of the neutron- γ pulse shape discrimination is a key issue to diminish the processing time in the DSP system, and it has been applied using the two-dimensional (2D) map. Linear discriminant function is used to determine the dividing line between neutron events and γ -ray events on a 2D map. In order to verify the validity of the dividing line determination, the pulse shape discrimination quality is evaluated. As a result, the γ -ray contamination in most of the beam heating phase was negligible compared with the statistical error with 10 ms time resolution.
本文言語 | English |
---|---|
論文番号 | 10D334 |
ジャーナル | Review of Scientific Instruments |
巻 | 81 |
号 | 10 |
DOI | |
出版ステータス | Published - 2010 10月 |
ASJC Scopus subject areas
- 器械工学