TY - JOUR
T1 - Non-invasive estimation of human left ventricular end-diastolic pressure
AU - Honda, Hideyuki
AU - Nakaya, Shigemitsu
AU - Kamada, Hideichi
AU - Hasegawa, Hideyuki
AU - Demachi, Jun
AU - Chikama, Hisao
AU - Sugimura, Koushirou
AU - Yamamoto, Yoshito
AU - Kumasaka, Norihisa
AU - Takita, Tamotsu
AU - Ikeda, Jun
AU - Kanai, Hiroshi
AU - Koiwa, Yoshiro
AU - Shirato, Kunio
PY - 1998/9/1
Y1 - 1998/9/1
N2 - Sato et al. (Electronic Letters 32, 949-950, 1996) reported that one can obtain a non-invasive estimate of left ventricular (LV) pressure at around end-diastole in an isolated canine preparation. In this study we examined whether this method can be applied to humans. Using the method proposed by Kanai et al. (IEEE. Trans. UFFC, 43, 791-810,1996), we detected small amplitude LV vibration from an ultrasonic pulse Doppler signal reflected from the interventricular septum in five patients (44-63 y.o., male;4, female;l). We measured the oscillation frequency of the LV wall through the wavelet transform of small amplitude LV vibration, and calculated LV pressure at around end-diastole from the values of oscillation frequency, internal radius and wall thickness using Mirsky's equation. The estimated LV pressures at around end-diastole were similar to end-diastolic pressure measured directly by cardiac catheterization. These results show the possibility that this method allows for the non-invasive estimate of LV pressure at around end-diastole, and furthermore provides the basis for future clinical applicability of this technique.
AB - Sato et al. (Electronic Letters 32, 949-950, 1996) reported that one can obtain a non-invasive estimate of left ventricular (LV) pressure at around end-diastole in an isolated canine preparation. In this study we examined whether this method can be applied to humans. Using the method proposed by Kanai et al. (IEEE. Trans. UFFC, 43, 791-810,1996), we detected small amplitude LV vibration from an ultrasonic pulse Doppler signal reflected from the interventricular septum in five patients (44-63 y.o., male;4, female;l). We measured the oscillation frequency of the LV wall through the wavelet transform of small amplitude LV vibration, and calculated LV pressure at around end-diastole from the values of oscillation frequency, internal radius and wall thickness using Mirsky's equation. The estimated LV pressures at around end-diastole were similar to end-diastolic pressure measured directly by cardiac catheterization. These results show the possibility that this method allows for the non-invasive estimate of LV pressure at around end-diastole, and furthermore provides the basis for future clinical applicability of this technique.
KW - End-diastolic pressure
KW - Left ventricle
KW - Myocardial elasticity
UR - http://www.scopus.com/inward/record.url?scp=17444436834&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=17444436834&partnerID=8YFLogxK
U2 - 10.1016/S1350-4533(98)00029-0
DO - 10.1016/S1350-4533(98)00029-0
M3 - Article
C2 - 9796956
AN - SCOPUS:17444436834
SN - 1350-4533
VL - 20
SP - 485
EP - 488
JO - Journal of Biomedical Engineering
JF - Journal of Biomedical Engineering
IS - 6
ER -