T1 - Polarization Behavior of Pd78Si16Cu6-xCrx Amorphous Alloys in an Artificial Body Fluid
AU - Hiromoto, Sachiko
AU - Numata, Hideo
AU - Tsai, An Pang
AU - Nakazawa, Kouzou
AU - Hanawa, Takao
AU - Sumita, Masae
N1 - Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 1999
Y1 - 1999
N2 - Ribbons of amorphous alloys, Pd78Si16Cu6 xCrx (x = 0, 2, 4 and 6 mol%), were polarized in an artificial body fluid, deaerated PBS ( - ), as the electrolyte to estimate the performance of the alloys as biomaterials with the intention of developing new high corrosion resistant amorphous alloys. Three kinds of surface conditions of amorphous alloys were prepared: as-received (by single roller melt spinning method), polished and just-polished (within 300 s after polishing). Polished crystalline alloys were also polarized as controls. Icorr (corrosion current density) and Icrit (critical passive current density) of the as-received amorphous alloys and the polished crystalline alloys decreased with increasing chromium content. Corrosion resistance of these alloys was improved by the addition of chromium. Icorr, Icrit and Ips (passivation current density) of the polished amorphous alloys were lower than those of the polished crystalline alloys and these values of the former alloys were independent of chromium content. This indicates that corrosion resistance of the polished amorphous alloys is higher in the artificial body fluid than that of the polished crystalline alloys. To determine the cathodic reactant on the as-received amorphous alloys in deaerated PBS ( - ), one of the alloys was polarized in deaerated 2.5 kmol%H2SO4. The cathodic Tafel slope in PBS( - ) was the same as that in H2SO4, indicating that the cathodic reactant in PBS ( - ) was identified as hydrogen ion. In addition, polarization curves of pure palladium, pure copper and pure chromium were examined to determine the anodic reaction. Ecorr (corrosion potential) of the pure palladium was similar to those of the alloys, suggesting that palladium ion is preferentially released from the alloys under the immersion in deaerated PBS ( - ). Icorr, and Icrit of the polished amorphous alloys were lower than those of the as-received amorphous alloys. To discuss the improvement in corrosion resistance by polishing, just-polished alloys were also polarized. The curves of the as-received and the just-polished alloys contained negative loop except the polished alloys. Icorr and Icrit of the just-polished alloys were slightly larger than those of the polished alloys. These results indicate that the surface morphology of the amorphous alloys changed during the exposure to air, causing the increase in corrosion resistance.
AB - Ribbons of amorphous alloys, Pd78Si16Cu6 xCrx (x = 0, 2, 4 and 6 mol%), were polarized in an artificial body fluid, deaerated PBS ( - ), as the electrolyte to estimate the performance of the alloys as biomaterials with the intention of developing new high corrosion resistant amorphous alloys. Three kinds of surface conditions of amorphous alloys were prepared: as-received (by single roller melt spinning method), polished and just-polished (within 300 s after polishing). Polished crystalline alloys were also polarized as controls. Icorr (corrosion current density) and Icrit (critical passive current density) of the as-received amorphous alloys and the polished crystalline alloys decreased with increasing chromium content. Corrosion resistance of these alloys was improved by the addition of chromium. Icorr, Icrit and Ips (passivation current density) of the polished amorphous alloys were lower than those of the polished crystalline alloys and these values of the former alloys were independent of chromium content. This indicates that corrosion resistance of the polished amorphous alloys is higher in the artificial body fluid than that of the polished crystalline alloys. To determine the cathodic reactant on the as-received amorphous alloys in deaerated PBS ( - ), one of the alloys was polarized in deaerated 2.5 kmol%H2SO4. The cathodic Tafel slope in PBS( - ) was the same as that in H2SO4, indicating that the cathodic reactant in PBS ( - ) was identified as hydrogen ion. In addition, polarization curves of pure palladium, pure copper and pure chromium were examined to determine the anodic reaction. Ecorr (corrosion potential) of the pure palladium was similar to those of the alloys, suggesting that palladium ion is preferentially released from the alloys under the immersion in deaerated PBS ( - ). Icorr, and Icrit of the polished amorphous alloys were lower than those of the as-received amorphous alloys. To discuss the improvement in corrosion resistance by polishing, just-polished alloys were also polarized. The curves of the as-received and the just-polished alloys contained negative loop except the polished alloys. Icorr and Icrit of the just-polished alloys were slightly larger than those of the polished alloys. These results indicate that the surface morphology of the amorphous alloys changed during the exposure to air, causing the increase in corrosion resistance.
KW - Amorphous alloy
KW - Artificial body fluid
KW - Biomaterials
KW - Corrosion current density
KW - Corrosion resistance
UR - http://www.scopus.com/inward/record.url?scp=0346968281&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0346968281&partnerID=8YFLogxK
U2 - 10.2320/jinstmet1952.63.3_352
DO - 10.2320/jinstmet1952.63.3_352
M3 - Article
AN - SCOPUS:0346968281
SN - 0021-4876
VL - 63
SP - 352
EP - 360
JO - Nippon Kinzoku Gakkaishi/Journal of the Japan Institute of Metals
JF - Nippon Kinzoku Gakkaishi/Journal of the Japan Institute of Metals
IS - 3
ER -