TY - JOUR
T1 - Potential complications of CAD/CAM-produced resin composite crowns on molars
T2 - A retrospective cohort study over four years
AU - Inomata, Miyu
AU - Harada, Akio
AU - Kasahara, Shin
AU - Kusama, Taro
AU - Ozaki, Akane
AU - Katsuda, Yusuke
AU - Egusa, Hiroshi
N1 - Publisher Copyright:
Copyright: © 2022 Inomata et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2022/4
Y1 - 2022/4
N2 - Purpose Evaluation of the clinical performance of computer-aided design/computer-aided manufacturing-produced resin composite crowns (CAD/CAM composite crowns) on molars with a particular focus on placement location. Methods A retrospective cohort study was performed based on the clinical records of patients with CAD/CAM composite crowns on molars (June 2016 to March 2021). The hazard ratios (HRs) and 95% confidence intervals (95% CIs) were estimated based the Cox proportional hazard model to evaluate the effect of tooth location on complication type and occurrence. Covariates included crown location (maxilla/mandible, distalmost tooth/not distalmost tooth, and first molar/second or third molar) and endodontically treated (nonvital) or untreated (vital) tooth. Results Overall, 362 crowns were evaluated (mean follow-up: 378 days, median: 286 days), and 106 crowns (29.3%) showed complications, most frequently crown debonding. The cumulative success and survival rates were 70.9% and 93.7%, respectively, after 1 year and 49.5% and 86.5%, respectively, after 3 years. There was no significant difference in the HRs and log-rank tests in the Kaplan–Meier curves based on crown location parameters (P > 0.05). However, placement on vital teeth was associated with higher risks than on nonvital teeth (HR, 1.55; 95% CI, 1.03–2.23). In addition, the cement as a covariate yielded a high HR. Conclusions The location of CAD/CAM composite molar crowns is unlikely a risk factor for complications; therefore, these crowns can be clinically applied to all molars. However, the application of such molar crowns to vital teeth and the use of a cement other than adhesive resin cement present risks.
AB - Purpose Evaluation of the clinical performance of computer-aided design/computer-aided manufacturing-produced resin composite crowns (CAD/CAM composite crowns) on molars with a particular focus on placement location. Methods A retrospective cohort study was performed based on the clinical records of patients with CAD/CAM composite crowns on molars (June 2016 to March 2021). The hazard ratios (HRs) and 95% confidence intervals (95% CIs) were estimated based the Cox proportional hazard model to evaluate the effect of tooth location on complication type and occurrence. Covariates included crown location (maxilla/mandible, distalmost tooth/not distalmost tooth, and first molar/second or third molar) and endodontically treated (nonvital) or untreated (vital) tooth. Results Overall, 362 crowns were evaluated (mean follow-up: 378 days, median: 286 days), and 106 crowns (29.3%) showed complications, most frequently crown debonding. The cumulative success and survival rates were 70.9% and 93.7%, respectively, after 1 year and 49.5% and 86.5%, respectively, after 3 years. There was no significant difference in the HRs and log-rank tests in the Kaplan–Meier curves based on crown location parameters (P > 0.05). However, placement on vital teeth was associated with higher risks than on nonvital teeth (HR, 1.55; 95% CI, 1.03–2.23). In addition, the cement as a covariate yielded a high HR. Conclusions The location of CAD/CAM composite molar crowns is unlikely a risk factor for complications; therefore, these crowns can be clinically applied to all molars. However, the application of such molar crowns to vital teeth and the use of a cement other than adhesive resin cement present risks.
UR - http://www.scopus.com/inward/record.url?scp=85127912298&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85127912298&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0266358
DO - 10.1371/journal.pone.0266358
M3 - Article
C2 - 35390093
AN - SCOPUS:85127912298
SN - 1932-6203
VL - 17
JO - PLoS One
JF - PLoS One
IS - 4 April
M1 - e0266358
ER -