T1 - Prediction of thermal coagulation from the instantaneous strain distribution induced by high-intensity focused ultrasound
AU - Iwasaki, Ryosuke
AU - Takagi, Ryo
AU - Tomiyasu, Kentaro
AU - Yoshizawa, Shin
AU - Umemura, Shin Ichiro
N1 - Publisher Copyright:
© 2017 The Japan Society of Applied Physics.
PY - 2017/7
Y1 - 2017/7
N2 - The targeting of the ultrasound beam and the prediction of thermal lesion formation in advance are the requirements for monitoring high-intensity focused ultrasound (HIFU) treatment with safety and reproducibility. To visualize the HIFU focal zone, we utilized an acoustic radiation force impulse (ARFI) imaging-based method. After inducing displacements inside tissues with pulsed HIFU called the push pulse exposure, the distribution of axial displacements started expanding and moving. To acquire RF data immediately after and during the HIFU push pulse exposure to improve prediction accuracy, we attempted methods using extrapolation estimation and applying HIFU noise elimination. The distributions going back in the time domain from the end of push pulse exposure are in good agreement with tissue coagulation at the center. The results suggest that the proposed focal zone visualization employing pulsed HIFU entailing the high-speed ARFI imaging method is useful for the prediction of thermal coagulation in advance.
AB - The targeting of the ultrasound beam and the prediction of thermal lesion formation in advance are the requirements for monitoring high-intensity focused ultrasound (HIFU) treatment with safety and reproducibility. To visualize the HIFU focal zone, we utilized an acoustic radiation force impulse (ARFI) imaging-based method. After inducing displacements inside tissues with pulsed HIFU called the push pulse exposure, the distribution of axial displacements started expanding and moving. To acquire RF data immediately after and during the HIFU push pulse exposure to improve prediction accuracy, we attempted methods using extrapolation estimation and applying HIFU noise elimination. The distributions going back in the time domain from the end of push pulse exposure are in good agreement with tissue coagulation at the center. The results suggest that the proposed focal zone visualization employing pulsed HIFU entailing the high-speed ARFI imaging method is useful for the prediction of thermal coagulation in advance.
UR - http://www.scopus.com/inward/record.url?scp=85025098768&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85025098768&partnerID=8YFLogxK
U2 - 10.7567/JJAP.56.07JF23
DO - 10.7567/JJAP.56.07JF23
M3 - Article
AN - SCOPUS:85025098768
SN - 0021-4922
VL - 56
JO - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes
JF - Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes
IS - 7
M1 - 07JF23
ER -