TY - JOUR
T1 - Rapid sorting of stainless steels by open-air laser-induced breakdown spectroscopy with detecting chromium, nickel, and molybdenum
AU - Kashiwakura, Shunsuke
AU - Wagatsuma, Kazuaki
N1 - Publisher Copyright:
© 2015 ISIJ.
PY - 2015
Y1 - 2015
N2 - Laser-induced breakdown spectroscopy (LIBS) is a promising method for rapid determination of compositions of stainless steels in steel scrap. LIBS is widely known as a method for elemental analysis that enables a rapid determination. It has several advantages such that it can work under ambient pressure, and specimens can be tested without any pre-treatment such as acid digestion, cleaning, or polishing of surface of specimens. We applied a laboratory-build LIBS system for sorting of six types of stainless steels. The standard reference materials of JISF FXS 324-334, 335-343, and 344-349, which are respectively Fe-Ni, Fe-Cr, and Fe-Mo binary alloys, were employed for making calibration lines of them. Considering spectral interferences from emission lines of the iron matrix in these alloys, seven emission lines could be chosen. Longer gate width, shorter delay time, high stability of pulse laser energy, and more number of laser shots can decrease the fluctuation of emission intensity. Utilizing these parameters mentioned above, the sorting of stainless specimens by detecting chromium, nickel, and molybdenum could be achieved.
AB - Laser-induced breakdown spectroscopy (LIBS) is a promising method for rapid determination of compositions of stainless steels in steel scrap. LIBS is widely known as a method for elemental analysis that enables a rapid determination. It has several advantages such that it can work under ambient pressure, and specimens can be tested without any pre-treatment such as acid digestion, cleaning, or polishing of surface of specimens. We applied a laboratory-build LIBS system for sorting of six types of stainless steels. The standard reference materials of JISF FXS 324-334, 335-343, and 344-349, which are respectively Fe-Ni, Fe-Cr, and Fe-Mo binary alloys, were employed for making calibration lines of them. Considering spectral interferences from emission lines of the iron matrix in these alloys, seven emission lines could be chosen. Longer gate width, shorter delay time, high stability of pulse laser energy, and more number of laser shots can decrease the fluctuation of emission intensity. Utilizing these parameters mentioned above, the sorting of stainless specimens by detecting chromium, nickel, and molybdenum could be achieved.
KW - LIBS
KW - Recycling
KW - Sorting
KW - Stainless
KW - Steel scrap
UR - http://www.scopus.com/inward/record.url?scp=84948751236&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84948751236&partnerID=8YFLogxK
U2 - 10.2355/isijinternational.ISIJINT-2015-316
DO - 10.2355/isijinternational.ISIJINT-2015-316
M3 - Article
AN - SCOPUS:84948751236
SN - 0915-1559
VL - 55
SP - 2391
EP - 2396
JO - Transactions of the Iron and Steel Institute of Japan
JF - Transactions of the Iron and Steel Institute of Japan
IS - 11
ER -