Story drift concentration and hysteresis energy for two story braced frame with buckling braces subjected to strong motion

Yoshihiro Kimura, Yohei Matsuo, Yasunori Nakazawa

研究成果: Article査読

3 被引用数 (Scopus)

抄録

In our previous researches, it is shown that story drift concentration is restrained by columns in two braced frames with buckling-restrained braces. For the two story braced frames with buckled braces, it is possible for the column to distribute the shear force on each story over height and the story drift concentration may be restrained, if it keeps elastic. In this paper, the equations of the drift concentration factor for two story braced frames with buckled braces have been developed from the equilibrium conditions of the frames subjected to lateral force. This paper clarifies the mechanism of the two story braced frames and the relationship between the drift concentration factor and the ratio of column flexural stiffness. Finally, the drift concentration with seismic response analysis is estimated with the equation for static drift concentration.

本文言語English
ページ(範囲)293-301
ページ数9
ジャーナルJournal of Structural and Construction Engineering
77
672
DOI
出版ステータスPublished - 2012 2月

ASJC Scopus subject areas

  • 建築
  • 建築および建設

フィンガープリント

「Story drift concentration and hysteresis energy for two story braced frame with buckling braces subjected to strong motion」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル