TY - JOUR
T1 - Surface modification method of microchannels for gas-liquid two-phase flow in microchips
AU - Hibara, Akihide
AU - Iwayama, Shinobu
AU - Matsuoka, Shinya
AU - Ueno, Masaharu
AU - Kikutani, Yoshikuni
AU - Tokeshi, Manabu
AU - Kitamori, Takehiko
N1 - Copyright:
Copyright 2008 Elsevier B.V., All rights reserved.
PY - 2005/2/1
Y1 - 2005/2/1
N2 - A capillarity restricted modification method for microchannel surfaces was developed for gas-liquid microchemical operations in microchips. In this method, a microstructure combining shallow and deep microchannels and the principle of capillarity were utilized for chemical modification of a restricted area of a microchannel. A hydrophobic-hydrophilic patterning in microchannels was prepared as an example for guiding gas and liquid flows along the respective microchannels. Validity of the patterning was confirmed by measuring aqueous flow leak pressure from the hydrophilic microchannel to the hydrophobic one. The leak pressure of 7.7-1.1 kPa agreed well with that predicted theoretically from the Young-Laplace equation for the microchannel depth of 8.6-39 μm. In an experiment to demonstrate usefulness and effectiveness of the method, an air bubble was first introduced into the hydrophilic microchannel and purged from the hydrophobic-hydrophilic patterned microchannels. Next, the patterning structure was applied to remove dissolved oxygen by contacting the aqueous flow with a nitrogen flow. The concentration of dissolved oxygen decreased with contact time, and its time course agreed well with numerical simulation. These demonstrations showed that the proposed patterning method can be used in general microfluidic gas-liquid operations.
AB - A capillarity restricted modification method for microchannel surfaces was developed for gas-liquid microchemical operations in microchips. In this method, a microstructure combining shallow and deep microchannels and the principle of capillarity were utilized for chemical modification of a restricted area of a microchannel. A hydrophobic-hydrophilic patterning in microchannels was prepared as an example for guiding gas and liquid flows along the respective microchannels. Validity of the patterning was confirmed by measuring aqueous flow leak pressure from the hydrophilic microchannel to the hydrophobic one. The leak pressure of 7.7-1.1 kPa agreed well with that predicted theoretically from the Young-Laplace equation for the microchannel depth of 8.6-39 μm. In an experiment to demonstrate usefulness and effectiveness of the method, an air bubble was first introduced into the hydrophilic microchannel and purged from the hydrophobic-hydrophilic patterned microchannels. Next, the patterning structure was applied to remove dissolved oxygen by contacting the aqueous flow with a nitrogen flow. The concentration of dissolved oxygen decreased with contact time, and its time course agreed well with numerical simulation. These demonstrations showed that the proposed patterning method can be used in general microfluidic gas-liquid operations.
UR - http://www.scopus.com/inward/record.url?scp=13244278085&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=13244278085&partnerID=8YFLogxK
U2 - 10.1021/ac0490088
DO - 10.1021/ac0490088
M3 - Article
C2 - 15679365
AN - SCOPUS:13244278085
SN - 0003-2700
VL - 77
SP - 943
EP - 947
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 3
ER -