抄録
In autumn 2003 data taking with the new Silicon Vertex Detector SVD2 in Belle started at the KEK-B energy-asymmetric e+ e- collider in Tsukuba, Japan. The detector works as expected, however, it was decided to produce replacement ladders for the inner two layers of the vertex detector which are most exposed to the high radiation doses from the beam. The new ladders are not merely reproducing the existing design but include some significant improvements. The readout electronics is designed in a FR4 hybrid board with a new heat transfer scheme in order to dissipate the heat produced in the VA1TA front-end readout chips. The flex circuits that connect the double-sided silicon sensors (DSSD's) with the hybrid boards were redesigned using a 2-layer technique which improved the production quality and lowered their costs significantly. Production and testing will he finished by the end of 2004 and will provide Belle with spare ladders as well as new expertise for possible future projects like e.g. developments for a high luminosity B-factory.
本文言語 | English |
---|---|
ページ(範囲) | 899-903 |
ページ数 | 5 |
ジャーナル | IEEE Nuclear Science Symposium Conference Record |
巻 | 2 |
出版ステータス | Published - 2004 |
外部発表 | はい |
イベント | 2004 Nuclear Science Symposium, Medical Imaging Conference, Symposium on Nuclear Power Systems and the 14th International Workshop on Room Temperature Semiconductor X- and Gamma- Ray Detectors - Rome, Italy 継続期間: 2004 10月 16 → 2004 10月 22 |
ASJC Scopus subject areas
- 放射線
- 核物理学および高エネルギー物理学