抄録
At the pile head part of a steel pipe pile, commonly a structure called slip prevention stoppers are attached to the inner surface of steel pipe pile in multiple steps, and filled with concrete in the pile body. However, there are no reports on experimentally verifying the structural performance of this structure. In this paper, we have confirmed the integration of steel pipe pile and filled concrete, ultimate bending strength and deformation capacity. We propose a method to calculate the ultimate bending strength and deformation capacity at the pile head part of steel pipe pile and show its validity.
寄稿の翻訳タイトル | EVALUATION OF ULTIMATE BENDING STRENGTH AND DEFORMATION CAPACITY AT CONCRETE FILLED PART OF STEEL PIPE PILE |
---|---|
本文言語 | Japanese |
ページ(範囲) | 737-748 |
ページ数 | 12 |
ジャーナル | Journal of Structural and Construction Engineering |
巻 | 87 |
号 | 798 |
DOI | |
出版ステータス | Published - 2022 |
Keywords
- Circular steel pipe pile
- Concrete filled steel pipe
- Limit distortion angle
- Plastic deformation capacity
- Ultimate bending strength
ASJC Scopus subject areas
- 建築
- 建築および建設